![tell Gate Control BASE 1000 Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/tell/gate-control-base-1000-series/gate-control-base-1000-series_installation-and-application-manual_1083878029.webp)
29
Available options:
Reading the settings from the device:
To read the settings from the device click on the “
Read settings
” button. This will
read all settings in all menus in the “
Device settings
” menu group.
Writing the settings into the device:
After changing the settings or entering new settings, in order to take effect in the
system, it is necessary to write the settings into the device by
clicking on the “
Write
settings
” button. This will write into the device the values changed in the menus in
the
“
Device settings
” menu group.
Please note that you have to write the settings into the device in order to be applied after
a change is made. Fo
r this, click on the “Write settings”
button.
Control:
Control mode:
Control mode 1
For one or two gates or one gate with two opening options (partial/total opening).
OUT1=N.O. (normally open)
OUT2=N.O. (normally open)
A
= OUT1 pulse length (seconds) => for opening gate A
B
= OUT2 pulse length (seconds) => for opening gate B
Selective control of outputs OUT1 and OUT2 by using caller identification and hidden
caller ID (private number). If the caller sends the caller ID, output OUT1 will be activated.
If the caller hides the caller ID (i.e. calls from a private number), output OUT2 will be activated.
Thereby, using this control mode you can control up to two different gates by call. Controlling
with hidden caller ID can be used by unlimited number of users (registered users too), since this
does not require user registration. You can hide the caller ID by dialing the
#31#
code in front of
the device’s phone number (e.g. #31#+3630….). If you want to control both outputs, for easier
handling you can add the
device’s phone number to your cellphone’s phonebook in both formats
(e.g. +3630…. and #31#+3630…).
The outputs provide an open contact by default and they become closed upon control.
The trigger pulse
length of output OUT1 can be configured by parameter ”
A
”, while the trigger
pulse
length of output OUT2 can be configured by parameter ”
B
”. The values are considered in
seconds.
The gate’s control board must close the gate automatically.
Attention! Anyone can control output OUT2 with hidden caller ID, not only registered
users!
This option should be used for low-security applications only, since an incoming call
(with hidden caller ID) made to the wrong number may also activate the output!
For better security, do not publish the device’s phone number.