UC864
UC864
UC864
UC864----E/G/WD/WDU
E/G/WD/WDU
E/G/WD/WDU
E/G/WD/WDU AT Commands Reference Guide
AT Commands Reference Guide
AT Commands Reference Guide
AT Commands Reference Guide
80304ST10041a Rev. 6
80304ST10041a Rev. 6
80304ST10041a Rev. 6
80304ST10041a Rev. 6 ---- 2010
2010
2010
2010----0
00
05
55
5----20
20
20
20
Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved.
Page 248 of 329
3.5.7.1.95.
Data Port Path
Data Port Path
Data Port Path
Data Port Path ---- #DAPT
#DAPT
#DAPT
#DAPT
#DAPT
#DAPT
#DAPT
#DAPT –
––
– Data Port
Data Port
Data Port
Data Port Path
Path
Path
Path
AT#DAPT= <psd
AT#DAPT= <psd
AT#DAPT= <psd
AT#DAPT= <psd
port>[,<csd port>]
port>[,<csd port>]
port>[,<csd port>]
port>[,<csd port>]
Set command sets the port to transmit and receive data when data call is
connected by ATD command
Parameter
<psd_port>
<psd_port>
<psd_port>
<psd_port> ---- packet switched data port
packet switched data port
packet switched data port
packet switched data port
0 – The port ATD is issued ( factory default )
1 – UART Data Port
2 – Telit USB Modem Port
3 – Telit USB Auxiliary Port
<csd_port>
<csd_port>
<csd_port>
<csd_port> ---- circuit switched data port
circuit switched data port
circuit switched data port
circuit switched data port
0 – The port ATD is issued ( factory default )
1 – UART Data Port
2 – Telit USB Modem Port
3 – Telit USB Auxiliary Port
AT#DAPT
AT#DAPT
AT#DAPT
AT#DAPT
Read command reports current setting value , in the format:
#DAPT: <psd_port>,<csd_port>
#DAPT: <psd_port>,<csd_port>
#DAPT: <psd_port>,<csd_port>
#DAPT: <psd_port>,<csd_port>
AT#DAPT=?
AT#DAPT=?
AT#DAPT=?
AT#DAPT=?
Test command reports the supported range of values for parameter
<psd_port>
<psd_port>
<psd_port>
<psd_port> and <csd_port>
<csd_port>
<csd_port>
<csd_port>
Note
Note
Note
Note
This command have no effect on the behavior of FAX call.
3.5.7.1.96.
Apply to New Operator Names
Apply to New Operator Names
Apply to New Operator Names
Apply to New Operator Names
#PLMNMODE
#PLMNMODE
#PLMNMODE
#PLMNMODE –
––
– Apply to New Operator Names
Apply to New Operator Names
Apply to New Operator Names
Apply to New Operator Names
AT#PLMNMODE=<
AT#PLMNMODE=<
AT#PLMNMODE=<
AT#PLMNMODE=<
mode>
mode>
mode>
mode>
Set command apply to new operator names depending on the parameter
<mode>
<mode>
<mode>
<mode>.
Parameter:
<mode>
<mode>
<mode>
<mode>
0 – previous operator names(factory default)
1 – new operator names
Note : if <mode>=1, AT+COPN command shows new operator names.
Note: Default value for UC864-G AT&T (08.01.127) is 1.
AT#PLMNMODE?
AT#PLMNMODE?
AT#PLMNMODE?
AT#PLMNMODE?
Read command returns current value of the parameter <mode>
<mode>
<mode>
<mode>.