+CPBR
+CPBR
+CPBR
+CPBR ---- Read Phonebook Entries
Read Phonebook Entries
Read Phonebook Entries
Read Phonebook Entries
where:
<index
<index
<index
<index
n
nn
n
>
>>
> - the location number of the phonebook entry
<number>
<number>
<number>
<number> - string type phone number of format <type>
<type>
<type>
<type>
<type>
<type>
<type>
<type> - type of phone number octet in integer format
129 - national numbering scheme
145 - international numbering scheme (contains the character "+
++
+")
<text>
<text>
<text>
<text> - the alphanumeric text associated to the number; used character
set should be the one selected with cCSCS
+CSCS
+CSCS
+CSCS....
Note: if “MC” is the currently selected phonebook memory storage, a
sequence of missed calls coming from the same number will be saved as
one missed call and +CPBR
+CPBR
+CPBR
+CPBR will show just one line of information.
Note: If all queried locations are empty (but available), no information text
lines will be returned, while if listing fails in an ME
ME
ME
ME error, +CME ERROR:
+CME ERROR:
+CME ERROR:
+CME ERROR:
<err>
<err>
<err>
<err> is returned.
AT+CPBR=?
AT+CPBR=?
AT+CPBR=?
AT+CPBR=?
Test command returns the supported range of values for parameters
<index
<index
<index
<index
n
nn
n
>
>>
> and the maximum lengths of <number>
<number>
<number>
<number> and <text>
<text>
<text>
<text> fields, in the
format:
+CPBR: (<minIndex>
+CPBR: (<minIndex>
+CPBR: (<minIndex>
+CPBR: (<minIndex> - <maxIndex>
<maxIndex>
<maxIndex>
<maxIndex>),<nlength>
<nlength>
<nlength>
<nlength>,<tlength>
<tlength>
<tlength>
<tlength>
where:
<minIndex>
<minIndex>
<minIndex>
<minIndex> - the minimum <index>
<index>
<index>
<index> number, integer type
<maxInde
<maxInde
<maxInde
<maxIndex>
x>
x>
x>- the maximum <index>
<index>
<index>
<index> number, integer type
<nlength>
<nlength>
<nlength>
<nlength> - maximum <number>
<number>
<number>
<number> field length, integer type
<tlength>
<tlength>
<tlength>
<tlength> - maximum <name>
<name>
<name>
<name> field length, integer type
Note
Remember to select the PB storage with +CPBS
+CPBS
+CPBS
+CPBS command before issuing
PB commands.
Example
AT+CPBS=”ME”
OK
AT+CPBS?
+CPBS: "ME",1,100
OK
AT+CPBR=?
+CPBR: (1-100),40,255
OK
AT+CPBR=1
+CPBR: 1,”01048771234”,129,”James”