UC864
UC864
UC864
UC864----E/G/WD/WDU
E/G/WD/WDU
E/G/WD/WDU
E/G/WD/WDU AT Commands Reference Guide
AT Commands Reference Guide
AT Commands Reference Guide
AT Commands Reference Guide
80304ST10041a Rev. 6
80304ST10041a Rev. 6
80304ST10041a Rev. 6
80304ST10041a Rev. 6 ---- 2010
2010
2010
2010----0
00
05
55
5----20
20
20
20
Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved.
Page 74 of 329
3.5.3.7.10.
Delay To DTR Off
Delay To DTR Off
Delay To DTR Off
Delay To DTR Off ---- S25
S25
S25
S25
S25
S25
S25
S25 ----Delay To
Delay To
Delay To
Delay To DTR Off
DTR Off
DTR Off
DTR Off
ATS25=[<time>]
ATS25=[<time>]
ATS25=[<time>]
ATS25=[<time>]
Set command defines the amount of time, in hundredths of second, that the
device will ignore the DTR
DTR
DTR
DTR for taking the action specified by command &D
&D
&D
&D.
Parameter:
<time>
<time>
<time>
<time> - expressed in hundredths of a second
0..255 - factory default value is 5.
Note: the delay is effective only if its value is greater than 5.
ATS25?
ATS25?
ATS25?
ATS25?
Read command returns the current value of S25 parameter
S25 parameter
S25 parameter
S25 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with
0s
3.5.3.7.11.
Disconnect Inactivity Tim
Disconnect Inactivity Tim
Disconnect Inactivity Tim
Disconnect Inactivity Timer
er
er
er ---- S30
S30
S30
S30
S30
S30
S30
S30 ----Disconnect Inactivity Timer
Disconnect Inactivity Timer
Disconnect Inactivity Timer
Disconnect Inactivity Timer
ATS30=[<tout>]
ATS30=[<tout>]
ATS30=[<tout>]
ATS30=[<tout>]
Set command defines the inactivity time-out in minutes. The device
disconnects if no characters are exchanged for a time period of at least
<tout>
<tout>
<tout>
<tout> minutes.
Parameter:
<tout>
<tout>
<tout>
<tout> - expressed in minutes
0 - disabled, disconnection due to inactivity is disabled (factory default).
1..127 - inactivity time-out value
ATS30?
ATS30?
ATS30?
ATS30?
Read command returns the current value of S30 parameter
S30 parameter
S30 parameter
S30 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with
0s
3.5.3.7.12.
Delay Before Forced Hang Up
Delay Before Forced Hang Up
Delay Before Forced Hang Up
Delay Before Forced Hang Up ---- S38
S38
S38
S38
S38
S38
S38
S38 ----Delay Before Forced Hang Up
Delay Before Forced Hang Up
Delay Before Forced Hang Up
Delay Before Forced Hang Up
ATS38=[<delay>]
ATS38=[<delay>]
ATS38=[<delay>]
ATS38=[<delay>]
Set command sets the delay, in seconds, between the device’s receipt of H
H
H
H
command (or ON
ON
ON
ON-to-OFF
OFF
OFF
OFF transition of DTR
DTR
DTR
DTR) and the disconnect operation.
Parameter:
<
<<
<de
de
de
delay
lay
lay
lay>
>>
> - acknowledge timer in units of seconds
0..254 - the device will wait <delay>
<delay>
<delay>
<delay> seconds for the remote device to
acknowledge all data in the device buffer before disconnecting
(factory default value is 20).
255 - the device doesn’t time-out and continues to attempt to deliver data
in the buffer until the connection is lost or the data is delivered.