GE866-QUAD Hardware User Guide
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.
Page 79 of 82
Mod. 0805 2011-07 Rev.2
14.3.
Moisture sensibility
The moisture sensitivity level of the Product is “3” according with standard
IPC/JEDEC J-STD-020,
take care of all the relative requirements for using this kind of components.
Moreover, the customer has to take care of the following conditions:
a) The shelf life of the Product inside of the dry bag is 12 months from the bag seal date, when
stored in a non-condensing atmospheric environment of < 40°C and < 90% RH.
b) Environmental condition during the production: <= 30°C / 60% RH according to IPC/JEDEC J-
STD-033B.
c) The maximum time between the opening of the sealed bag and the reflow process must be 168
hours if condition b) “IPC/JEDEC J
-STD-033B paragraph 5.2
” is respected.
d) Baking is required if conditions b) or c) are not respected
e) Baking is required if the humidity indicator inside the bag indicates 10% RH or more.