![Telit Wireless Solutions GE866-QUAD Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/telit-wireless-solutions/ge866-quad/ge866-quad_hardware-users-manual_1083653021.webp)
GE866-QUAD Hardware User Guide
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.
Page 21 of 82
Mod. 0805 2011-07 Rev.2
5.2.
Turning OFF the GE866-QUAD
Turning off of the device can be done in two ways:
•
General turn OFF
•
Processor turn OFF
General turn OFF
–
disconnect the power supply from the both power pins VBATT
and VBATT_PA at the same time. In this case all parts of the module are in OFF
condition, no power consumption is present.
Processor turn OFF
–
disconnect the power supply only from the power pin VBATT,
the power pin VBATT_PA can be connected to power supply, in this case a low, about
30uA, power consumption is present
Before either of both OFF procedures is applied, the AT#SYSHALT AT command must
be sent (see AT Commands Reference Guide, 80000ST10025a), after the OK response
message, wait for 10 seconds, then the module can be consider fully not operating
and at this moment is possible disconnect the Power Supply.
The following flow chart shows the proper turnoff procedure: