Measures Config.
32
3.3.1.2.2.- Extra Burst
The selection of this option provides a
power voltage increase of 1V
for a voltage of 13V (14V)
and of
1.5V
for a voltage of 18V (19.5V).
The extra burst is applicable both for terrestrial and satellite.
-
Powering with Extra Burst -
3.3.1.2.3.- DiSEqC
The DiSEqC protocol enables working with up to 16 input multi-switches. For the purpose, and
with the meter on the
satellite band
, on the power menu one should enable the voltage and tone
corresponding to the required polarity and band of the satellite.
As well as the chosen polarity and band, the multi-switch should be provided with information
on the satellite we intend to work with (the multi-switches group the different polarities in groups
=>
The equipment detects
voltage in the coaxial cable
. In this case, the message that
will appear is "
Vext
". This situation should be avoided.
=>
When the equipment detects a
short circuit
, it emits a sound signal, and the
message appearing in this case is "
Short Circuit
".
=>
When the
power consumption exceeds the maximum value allowed
, the
message appearing is "
Límit Exceeded
".
In the last two cases, the power is cut off, and automatic attempts at re-establishing it
are made every 3 seconds, approximately.