Telecell Installation Manual
Installation
TL-006175-PR Issue 5 © Telensa Ltd 2018
Page 17
LOW PROFILE
ANT-S-LP-A
ANT-S-LP-E
915MHz low profile (SMA)
868MHz low profile (SMA)
EASY FIT
ANT-S-EF-M
868MHz and 915MHz
easy fit (SMA)
1)
These Telecells are fitted inside the fixture securely, without compromising the
other components and positioned in a manner in keeping with the natural
workings.
Note:
This must be wired to the incoming supply and outgoing ballast/driver
along with the dimming wires as in section 2.2.2.
2)
Connect the antenna to the Telecell.
Note:
DO NOT OVER TIGHTEN RF CONNECTOR (0.3 – 0.6Nm).
3)
Turn on the mains supply to the Telecell and observe the Power On / DIM / Off
test cycle as described in section 1.7.1. It will turn on for 50 seconds, then turn off.
If dimmable: on 25 seconds, dim 25 seconds, then turns off.
4)
Record the necessary data as detailed under section 1.7. Data capture will be
dependent on available tools, for example: paper based or import via PDA.
5)
Affix the Telecell labels described in section 1.7 as necessary.
2.1.1
Two-Part Mounting
The maximum screw insertion depth is 12mm. Base mounting lugs are snap off, if
required, to enable mounting in confined spaces.
2.1.2
Two-Part Antenna Connection
The Two-Part version antenna connection uses an SMA connector, the plug is fitted to the
Telecell. Additional antenna cabling must use 50ohm coax with low loss at the operating
frequency (868 MHz for ETSI variants, 915MHz for FCC variants). It is recommended to
contact Telensa before using a longer antenna cable.