63
The Symbol and FSK deviation table is displayed on the right side of the
panel:
MSK:
When selecting MSK as current modulation type, the filter type can only be
selected as Gaussian
.
Multitone
Check the to set the radio button to set the multi-tone signal. Below is the
interpretion for the multi-tone parameters. Sample Rate: sample rate of multi-
tone modulation in MHz.
Range
: 0.002 to 37.5 MHz
Default
: 2 MHz
Freq Spacing: frequency spacing of multi-tone modulation in MHz.
Range
: 0 to Sample Rate/1.28 MHz
Default
: 1 MHz
Tone Number: tones number of multi-tone modulation.
Range
: 1 to 20
Default
: 1
Single Side: Turns ON or OFF single side modulation for multi-tone.
Default
: OFF