Typical Configuration using the DCI-101 module
Genie Nano
GV 400
NOTES:
1. Camera ports 1-4 provide POE (Power Over Ethernet). Do not connect the Genie Nano
camera’s power and ground to the DCI-101.
2. Power connections to the DCI-101 and GV 400 are not shown.
3. Use
A-CAB-GE-X
for camera Ethernet connections.
4. Use
A-CAB-G3-IO-X
cables for Genie Nano I/O. Camera Input1 is the expected trigger.
Cable wiring diagrams appear in the DCI-101 Quick Start Guide.
5. Use one
A-DCI-101
for every 2 cameras.
12
DCI-101 modules
GV 400 Installation