USER INTERFACE

13

WaveJet Touch Getting Started Guide

Descriptor Box

The 

Acquisition status bar

 appears above the grid. It shows information 

related to timebase, trigger mode (which determines if the acquisition is 

running or stopped), and sweeps count. 
The 

grid area

 displays the waveform traces. Each trace is color-coded 

to the channel and marked with the channel number. You can adjust the 

brightness (intensity) of the display to make trace lines more visible.

Cursor

 lines show where measurement points have been set. These 

white, dotted lines appear bold when they are selected. Turn the Adjust 

knob to reposition an active cursor. 

Trigger level 

(vertical axis) and 

trigger position

 (horizontal axis) indicators 

appear on the grid when a trigger is set, color-coded to match the input.
Other 

measurement readouts

 appear in a table below the grid when 

measurements have been applied to a trace.
The 

Trigger

 

status

 

bar

 appears immediately below the grid (or readout 

table if measurements are on) and shows the current trigger setup. It also 

shows cursor readouts when time cursors are applied.
Channel (1-4), and Math (M) 

descriptor boxes

 appear below the Trigger 

status bar and summarize current setups for each trace, as well as cursor 

readouts when amplitude cursors are applied. They are color-coded to 

the trace when the trace is on. Touch the descriptor box to open the 

corresponding set up menu.

Message

 bar appears along the bottom of the screen. Any error or 

processing messages appear here, along with input and acquisition 

memory information and the timestamp.

Channel Number

Gain Setting 

Pre-Processing Summary

Coupling

Trace Off

Level

Position

Trigger Indicators

Intensity 20%

Display Intensity

Intensity 80%

Offset

Trace On

Содержание WaveJet Touch

Страница 1: ...WaveJet Touch Getting Started Guide...

Страница 2: ......

Страница 3: ...r clients are encouraged to distribute and duplicate Teledyne LeCroy documentation for their own internal educational purposes WaveJet and Teledyne LeCroy are trademarks of Teledyne LeCroy Other produ...

Страница 4: ...ifications 2 Materials List 2 General Safety Information 3 Support 4 Set Up The Front of Your Oscilloscope 6 The Back of Your Oscilloscope 8 Carrying 9 Powering On Off 9 Connecting 9 Probes 10 Firmwar...

Страница 5: ...WaveJet Touch Oscilloscopes INTRODUCTION...

Страница 6: ...re at full 2 GS s sample rate The long memory makes the WaveJet Touch a great tool for viewing signals that have low frequency and or high frequency components Replay Mode The fast update rate shows r...

Страница 7: ...er cord shipped with this instrument and certified for the country of use Maintain ground This product is grounded through the power cord grounding conductor To avoid electric shock connect only to a...

Страница 8: ...CAUTION Do not attempt to clean internal parts Calibration The oscilloscope has automatic and self calibration routines When Auto calibration is enabled a recalibration will automatically occur whenev...

Страница 9: ...WaveJet Touch Oscilloscopes SET UP...

Страница 10: ...UP The Front of Your Oscilloscope Touch Screen Display Front Panel Power Button USB Port BNC Connectors for CH1 CH4 and EXT Ground and Calibration Output Terminals Tilting Feet A B C D E F G A B F G...

Страница 11: ...reen Display for an overview of its components The front panel houses buttons and knobs that control different oscilloscope settings Operate the instrument using front panel controls touch screen cont...

Страница 12: ...te control USBTMC Port for remote control Ethernet Port for remote control Kensington Lock Aux Out connector can be configured to send trigger or pass fail output AC Power Inlet for the AC line cord T...

Страница 13: ...he instrument if it will remain unused for a long period of time and at least once every six months to inspect and clean the plug Connecting After start up configure connections from the oscilloscope...

Страница 14: ...ck the download link and choose to Save the installer to a USB storage device 5 Insert the USB device into the port on the front of the oscilloscope 6 Press the front panel UTILITIES button and from t...

Страница 15: ...WaveJet Touch Oscilloscopes USER INTERFACE...

Страница 16: ...the right of the touch screen and a row of descriptor boxes along the bottom are touch activated Use them along with the front panel controls to operate the oscilloscope Acquisition Status Bar Cursor...

Страница 17: ...to match the input Other measurement readouts appear in a table below the grid when measurements have been applied to a trace The Trigger status bar appears immediately below the grid or readout tabl...

Страница 18: ...ger Status Bar Running Stopped Zoom Scale Trigger Delay Time Div Trigger Status Sweeps Count Trigger Status Time Cursor Readout Trigger Type Slope Source Message Bar Running Message Coupling Level Inp...

Страница 19: ...ose the menu Labels like this indicate a sub menu will open on top of the primary menu for further selection The appearance of menu options indicates what type of entry is required Icons or words set...

Страница 20: ...re closed The Help button opens WaveJet Touch Online Help Press Help then press the control for which you want help Touch any other control to close Help The Clear button clears sweeps and measurement...

Страница 21: ...WaveJet Touch Oscilloscopes BASICS...

Страница 22: ...splays the result of a math function applied to another trace M Press the front panel MATH button to turn on a math trace Adjust the trace by using the Math setup menu and front panel controls Use the...

Страница 23: ...turn on trace Turn to raise or lower Offset Push to return to zero Turn to raise or lower Vertical Scale V div Use touch menu to apply other Vertical settings to the trace such as Coupling or Bandwidt...

Страница 24: ...igger Delay Push to return Delay to zero Turn to raise or lower Horizontal Scale Time div Press to open Horizontal setup menu Use touch menu to make other acquisition settings such as Sampling Mode an...

Страница 25: ...Horizontal knobs to adjust zoom scale and offset Zoom opens in a second grid for every active trace Blue markers surround the portion of the original trace that is now zoomed to fit the width of the g...

Страница 26: ...preset period when there is no valid trigger NORMAL triggers repeatedly whenever all conditions are met SINGLE triggers once when all conditions are met Trigger type and level settings appear on the...

Страница 27: ...h cursor readout to a different source trace Time cursor readout appears at left edge of Trigger status bar Amplitude and Value cursor readouts appears on descriptor boxes Cursors Cursors set measurem...

Страница 28: ...stical measurements can be added to the readout table Pass Fail conditions can be set on measurement results see the WaveJet Touch Operator s Manual for instructions Press MEASURE to open the Measure...

Страница 29: ...n math functions and measurement parameters is that the result of math is always another waveform whereas the result of measurement is a number Press MATH to open Math setup menu Math trace M opens on...

Страница 30: ...w turn Waveform On A white reference trace appears on the grid along with the other active traces D Reference Waveforms Memories Reference waveforms are setups and waveform data stored in internal mem...

Страница 31: ...pture To configure how PRINT works press UTILITIES and choose Print from the Utilities menu To make a print just press PRINT Utilities Most oscilloscope properties settings can be found on the Utiliti...

Страница 32: ...utton and select from the menu Note Use the Utilities menu to change the style Graticule and brightness Intensity of the grid itself Save Recall Save Recall allows you to save channel setups and wavef...

Страница 33: ...WaveJet Touch Oscilloscopes REFERENCE...

Страница 34: ...d damage in transit 5 Mark the outside of the box with the shipping address given to you by Teledyne LeCroy be sure to add the following ATTN RMA code assigned by Teledyne LeCroy FRAGILE 6 If returnin...

Страница 35: ...st first examine the product and find that it is defective due to workmanship or materials and not due to misuse neglect accident or abnormal conditions or operation Teledyne LeCroy shall not be respo...

Страница 36: ...Field 3 Vrms 0 15 MHz 80 MHz EN 61000 4 11 2004 Mains Dips and Interruptions 0 1 cycle 70 25 cycles 0 250 cycles 4 5 1 To ensure compliance with all applicable EMC standards use high quality shielded...

Страница 37: ...oscilloscope has been certified by Underwriters Laboratories UL to conform to the following safety standard and bears the UL Listing Mark UL 61010 1 Third Edition Safety standard for electrical measu...

Страница 38: ...REFERENCE 34...

Страница 39: ......

Страница 40: ...2018 Teledyne LeCroy Inc All rights reserved 926062 00 Rev A January 2018...

Отзывы: