l
l
l
Note:
When selecting and using these apps, thoroughly review all the vendor
documentation. While Teledyne LeCroy has conducted testing of these apps, Teledyne
LeCroy has not completed full interoperability testing with our library of
Bluetooth
devices
and does not warrant the use of these apps with every device when using the following
procedures. Teledyne LeCroy does not provide support or maintenance for third party
apps. Any issues or questions should be directed to the app developer.
1. In the following steps Device Under Test 1 (DUT1) is the device sending the reference test file to
DUT2.
2. Download the third party app to DUT1 and follow the app vendor's instructions for installation and use.
3. Load the Audio Expert System reference test file
"Test_1.02_64.1kHz_16Bit.wav"
on DUT1.The test file is stored on the users computer In the directory "\Frontline <version
#>\Development Tools\Audio Expert Test Files\".
Note:
Reference test files are periodically updated. Shown here is an example.
Files delivered with your latest Frontline software version may have changed.
Contact Teledyne LeCroy Technical Support for information on the latest reference
file versions.
4. With the BPA 600 connected to the computer, configure the datasource, and follow procedures to
capture data.
5. Launch Audio Expert System by clicking on the
Control
window
.
6. Turn on Bluetooth on your DUTs, DUT1 and DUT2. Turn on the third party
Bluetooth
app for routing the
reference file over A2DP or HFP by following the vendor's directions.
7. Send the reference test file from DUT1 to DUT2 via the third party app.
8. Observe the events in the Audio Expert System™
Events Table
. Look for an event
Description
:
“TestIDFound : REF: Test ID 1.02, Channel Gain = -11.8 dB TermFreq=400.0”.
Note:
This is an example. The display may vary with the reference file version.
The Frontline analyzer has successfully detected the reference test signal and the system is locked into
reference mode.
TELEDYNE LECROY
Chapter 4 Capturing and Analyzing Data
197
Frontline BPA 600 Hardware & Software User Manual
Содержание Frontline BPA 600
Страница 1: ...Hardware and Software User Manual Revision Date 3 14 2017...
Страница 296: ...TELEDYNE LECROY Chapter 7 General Information 288 Frontline BPA 600 Hardware Software User Manual...
Страница 297: ...Appendicies Appendix A Application Notes 290 Frontline BPA 600 Hardware Software User Manual 289...
Страница 304: ...TELEDYNE LECROY Appendicies 296 Frontline BPA 600 Hardware Software User Manual...
Страница 310: ...TELEDYNE LECROY Appendicies 302 Frontline BPA 600 Hardware Software User Manual...
Страница 318: ...TELEDYNE LECROY Appendicies 310 Frontline BPA 600 Hardware Software User Manual...
Страница 328: ...TELEDYNE LECROY Appendicies 320 Frontline BPA 600 Hardware Software User Manual...
Страница 340: ......
Страница 348: ...340 Frontline BPA 600 Hardware Software User Manual Appendicies...