l
- The
Decode Pane
displays a detailed decode of the highlighted frame. Fields selected in the
Decode Pane
have the appropriate bit(s) or byte(s) selected in the
Radix
,
Binary
,
Character
, and
Event
panes
l
- The
Radix Pane
displays the
in the selected frame in either hexadecimal,
decimal or octal.
l
- The
Binary Pane
displays a binary representation of the logical data bytes.
l
- The
Character Pane
displays the character representation of the logical data bytes in either
ASCII, EBCDIC or Baudot.
l
- The Event Pane displays the physical data bytes in the frame, as received on the network.
By default, all panes except the
Event Pane
are displayed when the Frame Display is first opened.
Protocol Tabs
Protocol filter tabs are displayed in the
Frame Display
above the Summary pane.
l
These tabs are arranged in separate color-
coded groups. These groups and their
colors are General (white), Classic
Bluetooth
(blue),
Bluetooth
low energy (green),
802.11 (orange), USB (purple), NFC (brown)
and SD (teal). The General group applies to
all technologies. The other groups are
technology-specific.
l
Clicking on a protocol filter tab in the General group filters in all packets containing that protocol regardless of
each packet’s technology.
l
Clicking on a protocol filter tab in a technology-specific group filters in all packets containing that protocol on
that technology.
l
A protocol filter tab appears in the General group only if the protocol occurs in more than one of the
technology-specific tab groups. For example, if L2CAP occurs in both Classic Bluetooth and Bluetooth low
energy , there will be L2CAP tabs in the General group, the Classic Bluetooth group, and the Bluetooth low
energy group.
Select the
Unfiltered
tab to display all packets.
There are several special tabs that appear in the
Summary Pane
when certain conditions are met. These tabs
appear only in the General group and apply to all technologies. The tabs are:
l
Bookmarks
appear when a bookmark is first seen.
l
Errors
appear when an error is first seen. An error is a physical error in a data byte or an error in the
protocol decode.
l
Info
appears when a frame containing an Information field is first seen.
The tabs disappear when the capture buffer is cleared during live capture or when decoders are reloaded, even if
one of the tabs is currently selected. They subsequently reappear as the corresponding events are detected.
Chapter 4 Capturing and Analyzing Data
TELEDYNE LECROY
Frontline 802.11 Hardware & Software User Manual
63
Содержание Frontline 802.11
Страница 1: ...Hardware and Software User Manual Revision Date 12 14 2016 ...
Страница 24: ...18 Frontline 802 11 Hardware Software User Manual TELEDYNE LECROY Chapter 2 Getting Started ...
Страница 52: ...46 Frontline 802 11 Hardware Software User Manual TELEDYNE LECROY Chapter 3 Configuration Settings ...
Страница 154: ...148 Frontline 802 11 Hardware Software User Manual TELEDYNE LECROY Chapter 4 Capturing and Analyzing Data ...
Страница 204: ...198 Frontline 802 11 Hardware Software User Manual TELEDYNE LECROY Chapter 7 General Information ...
Страница 205: ...Appendicies Appendix A Application Notes 200 Frontline 802 11 Hardware Software User Manual 199 ...
Страница 207: ...Appendicies TELEDYNE LECROY Frontline 802 11 Hardware Software User Manual 201 ...
Страница 217: ......