The larger your task size the more benefit realized in cost avoidance and efficient resource usage through
automation of the Frontline ComProbe protocol analyzers. The extra effort to program the test automation is
minimal compared to the time saved to manually test.
Frontline's Automation Server provides the means to programmatically control ComProbe software and hardware
in a client-server configuration. The Automation Server is provided when you purchase your ComProbe analyzer,
and is stored in the Frontline ComProbe Protocol Analysis System directory. The ComProbe Automation Server
Protocol Programmers Guide is located in this same directory. The process for automating your data capture is
accomplished in three steps.
1. Connect the ComProbe hardware to a computer running ComProbe software and the Automation Server.
2. Launch the Automation Server program. The program will listen to the commands from the Automation
Client program and according control the ComProbe software.
3. Write your Automation Client program (use the template provided with the installation package) and run
it.
As long as there is no change in the programmed capture process, step 3 can be repeated reliably and without
deviation. Should the test plan change, the program written in step 1 can serve as a template to minimze
development timeand to provide quality control tracability.
A.1.1 Automation Server Topology
Figure 2 - Automation Server on a
Single PC
The Automation Server executes the commands issued by a user-created
Automation client script. The client script can run either on the local PC or on
a remote over a TCP/IP connection. The Automation Client program can be
written in any language and uses the syntax defined in the ComProbe
Automation Server Protocol Programmers Guide. The client will bypass the
local Microsoft Windows interface and interacts directly with ComProbe
software. One or more instances of the ComProbe software must be running
along with one instance of the Automation Server.
Figure 3 - Automation Server Using Two PCs
A.1.2 Writing Automation Script
Automation scripting is done by persons with knowledge of TCP socket communications. The process automation
is achieved by writing a client application which talks over a TCP network socket connection with the ComProbe
Automation Server.
Delivered in your ComProbe installation package is a sample script SampleClient.tcl. This script is located in your
installation directory. This is typically located at C:\Program Files (x86)\Frontline Test System II\Frontline
ComProbe Protocol Analysis System
[your version]
\Development Tools\. On 32-bit Windows or Windows XP the
root installation folder is "C:\Program Files\".
TELEDYNE LECROY
Appendicies
203
Frontline 802.11 Hardware & Software User Manual
Содержание Frontline 802.11
Страница 1: ...Hardware and Software User Manual Revision Date 12 14 2016 ...
Страница 24: ...18 Frontline 802 11 Hardware Software User Manual TELEDYNE LECROY Chapter 2 Getting Started ...
Страница 52: ...46 Frontline 802 11 Hardware Software User Manual TELEDYNE LECROY Chapter 3 Configuration Settings ...
Страница 154: ...148 Frontline 802 11 Hardware Software User Manual TELEDYNE LECROY Chapter 4 Capturing and Analyzing Data ...
Страница 204: ...198 Frontline 802 11 Hardware Software User Manual TELEDYNE LECROY Chapter 7 General Information ...
Страница 205: ...Appendicies Appendix A Application Notes 200 Frontline 802 11 Hardware Software User Manual 199 ...
Страница 207: ...Appendicies TELEDYNE LECROY Frontline 802 11 Hardware Software User Manual 201 ...
Страница 217: ......