UM_NBASE-T_C
OLOUR
REV.E
09/2018
P
A G E
|
62
B.2
Synchronization modes with Fixed Exposure Time
In these modes, the rising edge of the Trigger (internal or External) starts the readout process (T
pix
) of the
previous integration. The Real exposure time (Tint
real
) is finally equal to the Line Period (
T
per
) even if it’s
delayed from (
T
x
+ T
d
) from the rising edge of the incoming Line Trigger.
B.3
Timing Values
Label
Min
Unit
T
pix
5
µs
T
x
3,1
µs
T
h
0,120
µs
T
ht
T
pix
µsec
T
d
1.1
µs
Line Trigger
Ext. or Internal
T
d
T
per
=
T
int
T
h
Digital Conversion
T
pix
Tint
real
T
x
Exposure Time
Internal
Synchro
Mode
Exposure
Mode Off
In the
Camera /
sensor
Digital Conversion
T
pix
T
x
2,5µ
s
Tint
prog
1,5µ
s
Tint
real
Tper
min
5µs
15µs
12µs