UM_NBASE-T_C
OLOUR
REV.E
09/2018
P
A G E
|
41
0x4E0583B4
E2v_Counter1ResetActivation
4
RW
Set the Counter 1 Reset Activation mode :
0 : Rising Edge
1 : Falling Edge
2 : Any Edge
3 : Level High
4 : Level Low
0x4E06067C
Counter1LockSource
4
RW
Set the Source for the Counter 1 Lock :
0 : Off
1 : Line Trigger 1
2 : Line Trigger 2
3 : Frame Trigger
4 : FLO (Exposure Active in the Sensor)
6 : Counter 2 End
7 : Timer 1 End
8 : Timer 2 End
9 : L3
10 : L4
11 : L5
12: L6
13 : Frame Valid
14 : Acquisition Active
15 : Software (Use Counter1LockSoftware register)
16 : Rotary Encoder Output
0x4E060688
Counter1LockActivation
4
RW
Set the Counter 1 Lock Activation mode :
3 : Level High
4 : Level Low
0x4E060690
Counter1LockSoftware
4
RW
Software Register to Lock Counter 1
0x4E0583BC
Counter1Reset
4
RW
Reset command
0x4E0583CC
Counter1ValueAtReset
4
WO
Counter 1 Value at Reset
0x4E0583C4
e2v_Counter1Value
4
RO
Current counter 1 Value
0x4E0583D4
E2v_Counter1Duration
4
RW
Counter 1 duration set by user
0x4E0584A4
Counter1Enable
4
RW
Counter 1 Enable :
0 : Off
1 : On
0x4E0584D0
Counter1Software
4
RW
Software command to Reset Counter1 by Software
Counter 2
0x4E0583A0
Counter2EventSource
4
RW
Event Source to be counted :
1 : Line Trigger 1
2 : Line Trigger 2
3 : Frame Trigger
4 : FLO (Exposure Active in the Sensor)
5 : Counter 2 End
7 : Timer 1 End
8 : Timer 2 End
9 : L3
10 : L4
11 : L5
12: L6
13 : Frame Valid
16 : Rotary Encoder Output
0x4E0583A8
Counter2EventActivation
4
RW
Set the Counter 2 Source Activation mode :
0 : Rising Edge
1 : Falling Edge
2 : Any Edge
0x4E0583B0
Counter2ResetSource
4
RW
Set the Source for the Counter 2 Reset :
0 : Off
1 : Line Trigger 1
2 : Line Trigger 2
3 : Frame Trigger
5 : Counter 2 End
7 : Timer 1 End
8 : Timer 2 End