UM_NBASE-T_C
OLOUR
REV.E
09/2018
P
A G E
|
42
9 : L3
10 : L4
11 : L5
12: L6
13 : Frame Valid
14 : Acquisition Active
15 : Software (Use Counter2Software register)
0x4E0583B8
Counter2ResetActivation
4
RW
Set the Counter 2 Reset Activation mode :
0 : Rising Edge
1 : Falling Edge
2 : Any Edge
3 : Level High
4 : Level Low
0x4E060680
Counter2LockSource
4
RW
Set the Source for the Counter 2 Lock :
0 : Off
1 : Line Trigger 1
2 : Line Trigger 2
3 : Frame Trigger
4 : FLO (Exposure Active in the Sensor)
6 : Counter 2 End
7 : Timer 1 End
8 : Timer 2 End
9 : L3
10 : L4
11 : L5
12: L6
13 : Frame Valid
14 : Acquisition Active
15 : Software (Use Counter2LockSoftware register)
16 : Rotary Encoder Output
0x4E06068C
Counter2LockActivation
4
RW
Set the Counter 2 Lock Activation mode :
3 : Level High
4 : Level Low
0x4E060694
Counter2LockSoftware
4
RW
Software Register to Lock Counter 2
0x4E0583C0
Counter2Reset
4
RW
Reset command
0x4E0583D0
Counter2ValueAtReset
4
RW
Counter 2 Value at Reset
0x4E0583C8
e2v_Counter2Value
4
RW
Current counter 2 Value
0x4E0583D8
E2v_Counter2Duration
4
RW
Counter 2 duration set by user
0x4E0584A8
Counter2Enable
4
RW
Counter 2 Enable :
0 : Off
1 : On
0x4E0584D4
Counter2Software
4
RW
Software command for a Reset Source set to Software