Instructions myintercom Plus IP video door intercom
Installation
GB
Ethernet connector
Usually, an RJ-45 connector is used to establish
LAN connection ( ). You may also connect
the individual cores to the connection interface
using a terminal block : The network is
connected to the terminals marked 1 (orange-
white), 2 (orange), 3 (green-white) and 6 (green)
according to EIA/TIA
specification 568 B. The number indicated
refers to the pin position of the RJ-45 plug / the
RJ-45 socket.
Alternative Ethernet connection
It is not possible to simultaneously use the
RJ 45 socket and the terminal block. This may
lead to a defect in the door intercom station!
Connecting the open door function
Connection option for an open door function
(12 V DC/AC max. 9 W). Cf. Chapter "3.3. Open
door/Relay/Gong" on page 63.
Relay 1 (open door function relay)
Potential-free connection (max. load is
max. 60VDC / 50 VAC, max. 60 W, 62.5 VA, max.
2A) for an open door function, to be activated
via the “myintercom2 app. Cf. Chapter "3.3.
Open door/Relay/Gong" on page 63.
Relay 2 (additional relay)
Potential-free connection (max. load is max.
60VDC / 50 VAC, max. 60 W, 62.5 VA, max. 2A)
to be activated via the “myintercom” app. Cf.
Chapter "3.3. Open door/Relay/Gong" on page
63.