GB
49
FINAL TESTING
IMPORTANT RECOMMENDATIONS CONCERNING INSTALLATION
DISPOSAL
A final test should always be made after completing all programming procedures.
- Check correct operation of the protection devices (anti-crushing system, stop button, photocells, sensitive edges etc.)
- Check correct operation of the signalling devices (flashing lights, gate open indicator etc.)
- Check correct operation of the control devices (S/S pushbutton, radio controls etc.)
Only qualified personnel having the legal requirements must install the automation according to the principles of good workmanship and in conformity
with the machinery directive 98/37/CE and standards EN 12453 and EN 12445.
Check that the existing structures (posts, hinges, leaves) are stable in relation to the forces developed by the motor.
Check that suitably robust limit stops have been installed for end of gate opening and closing.
Check the state of the cables that are already present in the system.
Analyse the hazards connected with the automation system and adopt the necessary safety and signalling devices accordingly.
Install the commands (e.g. the key selector) so that the user is not placed in a hazardous area when using them.
Upon completion of the installation, test the safety, signalling and release devices of the automation system several times.
Apply the CE label or plate with information regarding the hazards and identification data on the automation.
Give the end user the instructions for use, the safety recommendations and the CE declaration of conformity.
Ensure that the user has understood the correct automatic, manual and emergency operation of the automation system.
Inform the user in writing (e.g. in the instructions for use) of any unprotected residual risks and of foreseeable misuse.
Inform the user in writing (in the use instructions for example):
- Of possible non secluded residual risks and of foreseeable improper use.
- To disconnect the power supply when cleaning the area that is automated or when performing small maintenance operations (e.g.: repainting).
- To frequently control that no visible damage has occurred to the automation, and to inform the installer immediately if damage is noticed.
- Not to allow children to play in the vicinity of the automation.
- Prepare a maintenance schedule for the automation installation (at least once every 6 months for the safety devices), recording the work carried out
in a special book.
This product is made up of various components that could contain pollutants. Dispose of properly!
Make enquiries concerning the recycling or disposal of the product, complying with the local laws in force.
- With deceleration enabled and after a reset (or power failure) the control unit activates an opening cycle at low speed to locate the reference
points (end stops).
CE DECLARATION OF CONFORMITY
The undersigned Augusto Silvio Brunello, Legal representative of the company:
TELCOMA s.r.l. Via Luigi Manzoni 11, 31015 Conegliano (TV) ITALY
declares that the product:
for use as: Gate automation control unit
complies with the essential requirements of section 3 and relative measures of Directive 1999/5/CE, if used for the purpose for which it has been
designed.
complies with the essential requirements of Directive 89/336 (EMC), EN 61000-6-3, EN 61000-6-1 and subsequent amendments, if used for the
purpose for which it has been designed.
complies with the essential requirements of Directive 73/23 (LVD), EN 60335-1 and subsequent amendments, if used for the purpose for which it
has been designed.
Place and date
Legal representative
Model:
:
Conegliano, 18/09/2006
Augusto Silvio Brunello