8
Serial Number (Status Only)
This status information is the electronic serial number of the transmitter
PCB. This number can be exchanged with
TEL-MAR
to purchase extra
licensable features, such as upgrades to support AES encryption.
Chaining (Status Only)
This field reports the status of the chaining input to the
DLC-7000
transmitter, and is not active in current units.
Options
Engineering
– provides access to further diagnostic and calibration
features. The
Diagnostic
and
Power calibration
pages must not be
altered. The
Advanced Options
under the Engineering menu allow the
user to
Change RS232 address
, which can be useful when connecting
multiple units together via a multi drop RS485 bus for control purposes.
The
Serial control
dialogue box allows the user to change timeouts
used during the serial communications between the unit and the
controller.
Enable Polling
– selecting this option makes the control application
automatically refresh the data presented to the user every few seconds.
Polling Options –
selecting this option allows the user to define
parameters to be regularly polled.
Write Encryption Key
– opens a dialogue box for entering an ABS or
AES scrambling key, as 32 ASCII hexadecimal characters (0…F)
Write License Code
– open a further box for entering license codes for
the activation of licensable features (e.g. AES scrambling) in the
transmitter. Contact
TEL-MAR
for support in applying new licenses as
required.
Restore Defaults
– restores factory default settings in the transmitter.
File
Set Icon Source, Set logo source, Set logo size and Set application
title –
allow the user to define a controller branding
Exit
– exits the
DLC
transmitter
control application