NOTE
. If the DHCP/BOOTP server assigns a
dynamic
IP address, then the value
in the Instrument IP Address field may be different each time you power on the
oscilloscope. This is not a problem if you are mostly sending hard copy to a
network printer. However, if you intend to remotely control the oscilloscope, a
static
IP address is more convenient, as the oscilloscope IP address does not
change, making it easier for remote devices to access the oscilloscope.
Ethernet Network Settings: DHCP/BOOTP Not Supported.
If your network does not
support DHCP/BOOTP, you must enter the Ethernet settings manually. You can
obtain these settings from your network administrator by using the form on
page 1--8.
The following procedure presumes that you have installed the TDS3EM
Communication Module and cable into a TDS3000 Series oscilloscope.
TDS3000B and TDS3000C series oscilloscopes simply require an RJ-45
connector with 10BaseT cable attached to the oscilloscope Ethernet port.
Do these steps to enter the Ethernet parameters:
1.
Use the Ethernet network setup form on page 1--8 to request the necessary
network information from your network administrator.
2.
Power on the oscilloscope.
3.
Push the
UTILITY
front panel button.
4.
Push the
System
screen button to select
I/O
.
5.
Push the
Ethernet Network Settings
screen button.
6.
Push the
Change Instrument Settings
side button to display the Instrument
Setup dialog box.
7.
Push the side menu
↑
and
↓
buttons to select a field to edit.
8.
Enter the required information from the Ethernet network setup form into
each field:
H
The general purpose knob selects a character in the character list. The list
of available characters changes depending on which field is selected.
H
The
Enter Character
button enters the selected character from the
character list at the cursor position in the current field. You can also use
the
SELECT
button next to the general purpose knob to enter the
selected character.
H
The
←
and
→
buttons move the cursor left or right in the current field.
Содержание TDS3000 Series
Страница 8: ...Table of Contents vi TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 10: ...Preface viii TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 38: ...Getting Started 1 28 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 82: ...Command Groups 2 44 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 388: ...Status and Events 3 20 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 402: ...Appendix D Factory Initialization Settings D 4 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...