Command Descriptions
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
2- 153
ITU601:INPUT:SIGnalstrength? (Query Only)
(TDS3000B and TDS3000C Series with TDS3SDI Only)
Returns the value of the TDS3SDI input signal strength parameter. The signal
strenght value is an integer in the range of 0 to 5, where 0 = no signal present
and 5 = maximum signal strength.
TDS3SDI
ITU601:INPUT:SIGnalstrength?
ITU601:INPUT:SIGNALSTRENGTH?
might return the response
ITU601:INPUT:SIGNALSTRENGTH 1
.
ITU601:INPUT:STATE? (Query Only)
(TDS3000B and TDS3000C Series with TDS3SDI Only)
Returns the TDS3SDI input signal state value. Valid return values are MISSING
(no 601 digital signal is present), S525 (an S525 601 digital signal is present),
and S625 (an S625 601 digital signal is present).
TDS3SDI
ITU601:INPUT:STATE?
ITU601:INPUT:STATE?
might/sets return the response
ITU601:INPUT:STATE? MISSING
, indicating that
there is no 601 digital video signal connected to the TDS3SDI module.