Command Descriptions
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
2- 189
NOTE
. The oscilloscope generates a hard copy only on the first violation that
causes the pass/fail test to fail. To generate a hard copy file for every violation
occurrence, set MASK:TESt:REPeat to ON and set MASK:TESt:WAVEform to 1.
Use this technique only when the expected number of violations is small and the
violation occurs intermittently.
Mask
MASK:TESt:HARDCopy { OFF | ON | <NR1> }
MASK:TESt:HARDCopy?
OFF
turns off generate hard copy on failure.
ON
turns on generate hard copy on failure.
<NR1>
is an integer number where NR1 = 0 turns off generate hard copy on
failure, and NR1
≠
0 turns on generate hard copy on failure.
MASK:TEST:HARDCOPY ON
turns on generate hard copy on failure.
MASK:TESt:REPeat
(Requires TDS3TMT)
Sets or returns the repeat pass/fail test on completion mode. When enabled, this
command repeats the pass/fail test cycle at the completion of the previous test
cycle.
Mask
MASK:TESt:REPeat { OFF | ON | <NR1> }
MASK:TESt:REPeat?
OFF
turns off repeat on completion.
ON
turns on repeat on completion.
<NR1>
is an integer number where NR1 = 0 turns off repeat on completion, and
NR1
≠
0 turns on repeat on completion.
Group
Syntax
Arguments
Examples
Group
Syntax
Arguments
Содержание TDS3000 Series
Страница 8: ...Table of Contents vi TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 10: ...Preface viii TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 38: ...Getting Started 1 28 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 82: ...Command Groups 2 44 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 388: ...Status and Events 3 20 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Страница 402: ...Appendix D Factory Initialization Settings D 4 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...