General safety summary
General safety summary
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as speci
fi
ed.
Only quali
fi
ed personnel should perform service procedures.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component
manuals for warnings and cautions related to operating the system.
To avoid
fi
re or personal injury
Use proper power cord.
Use only the power cord speci
fi
ed for this product and certi
fi
ed for the country of use.
Connect and disconnect properly.
Do not connect or disconnect probes or test leads while they are connected to a voltage
source.
Connect and disconnect properly.
De-energize the circuit under test before connecting or disconnecting the current probe.
Connect and disconnect properly.
Connect the probe output to the measurement instrument before connecting the probe to the
circuit under test. Connect the probe reference lead to the circuit under test before connecting the probe input. Disconnect the probe
input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement instrument.
Ground the product.
This product is indirectly grounded through the grounding conductor of the mainframe power cord. To avoid
electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output
terminals of the product, ensure that the product is properly grounded.
Observe all terminal ratings.
To avoid
fi
re or shock hazard, observe all ratings and markings on the product. Consult the product
manual for further ratings information before making connections to the product.
20 A Current Probes Instruction Manual
v
Содержание TCP0020
Страница 1: ...x TCP0020 TCP2020 50 MHz 20 Amp AC DC Current Probes ZZZ Instruction Manual P071300200 071 3002 00...
Страница 2: ......
Страница 6: ......
Страница 10: ...Table of Contents iv 20 A Current Probes Instruction Manual...
Страница 22: ...Compliance Information xvi 20 A Current Probes Instruction Manual...
Страница 80: ...Specifications Figure 2 Typical insertion impedance versus frequency 56 20 A Current Probes Instruction Manual...
Страница 81: ...Specifications Figure 3 Maximum peak pulse versus pulse width 20 A Current Probes Instruction Manual 57...
Страница 83: ...Specifications Figure 4 Mechanical dimensions 20 A Current Probes Instruction Manual 59...