Waveform display settings
4.
Use the
Multipurpose
knob to change and set the
Persist Time
value. The range is
Auto
(which is the same as 0 s), 0 s -
10 s (in one second increments), and in
fi
nity.
5.
To clear the persistence of the displayed waveform, select and click
Clear Persistence
. This does not change the
persistence setting, but just clears the displayed waveform persistence data.
Waveform persistence tip
To quickly clear the displayed waveform persistence data, push
Single
, then push
Run/Stop
to restart active waveform
acquisition.
The XY display mode
The XY display mode plots the signal amplitude of channel 1 (X) against the amplitude of channel 2 (Y), where channel 1
is the horizontal axis and channel 2 is the vertical axis. XY display mode is useful for showing signal phase or frequency
relationships between periodic signals. The resulting XY plots are called Lissajou patterns.
You can display Ch 1 versus Ch 2. On four-channel models, you can also display Ch 3 versus Ch 4.
1.
Select the two signal sources that you
want to plot. Push the
Vertical Position
knob for each channel to set the ground
reference of both signals to 0 V (center
horizontal graticule) so that the XY plot
is centered on the screen.