Commands Listed in Alphabetical Order
Group
Vertical
Syntax
CH<x>:FILTer:VALue { NONe | CPRI7373 | ENET103R4 |
ENET103R10 | ENET257R4 | ENET1250 | ENET2500 | ENET3125 |
ENET41250 | ENET9953 | ENET10313 | ENET11096 | FC1063 |
FC2125 | FC3188 | FC4250 | FC8500 | FC8500FINAL | FC10519 |
FC11317 | FC14025 | FC28050 | FEC2666 | FEC42657 | FEC43018
| FEC10664 | FEC10709 | FEC12500 | FPELECOUT | INF2500 |
INF5000 | INF14063 | INF25781 | INFIniband | PCIX2500 |
PCIX6250 | OBSAI6144 | OC1 | OC3 | OC9 | OC12 | OC18 | OC24
| OC36 | OC48 | OC96 | OC192 | OC768 | ORR32G | OTU27952 |
SATA1500 | SATA3000 | SATA6000 | SFEC12500 | VSR5_3318 }
CH<x>:FILTer:VALue?
Related Commands
Arguments
NONe
disables reference-receiver
fi
ltering.
CPRI7373
selects a reference-receiver
fi
lter for the 7.373 Gb/s bit rate, in
accordance with the Wireless Base Station CPRI 7.373 standard.
ENET103R4
selects a reference-receiver
fi
lter for the 10.3125 Gb/s bit rate, in
accordance with the Ethernet 40GBASE-LR4/SR4 standard.
ENET103R10
selects a reference-receiver
fi
lter for the 10.3125 Gb/s bit rate, in
accordance with the Ethernet 100GBASE-SR10 standard.
ENET257R4
selects a reference-receiver
fi
lter for the 25.78125 Gb/s bit rate, in
accordance with the Ethernet 100GBASE-ER4/LR4 standard.
ENET1250
selects a reference-receiver
fi
lter for the 1.250 Gb/s bit rate, in
accordance with the IEEE 802.3ae-2002 standard.
ENET2500
selects a reference-receiver
fi
lter for the 2.500 Gb/s bit rate (2x
Gigabit Ethernet).
ENET3125
selects a reference-receiver
fi
lter for the 3.125 Gb/s bit rate, in
accordance with the IEEE 802.3ae-2002 standard.
ENET9953
selects a reference-receiver
fi
lter for the 9.95328 Gb/s bit rate, in
accordance with the IEEE 802.3ae-2002 standard.
ENET10313
selects a reference-receiver
fi
lter for the 10.3125 Gb/s bit rate, in
accordance with the IEEE 802.3ae-2002 standard.
ENET11096
selects a reference-receiver
fi
lter for the 11.095728 Gb/s bit rate,
which is a forward error-correction rate for 10GbE (10.3125 Gb/s per IEEE
802.3ae-2002 standard).
ENET41250
selects a reference-receiver
fi
lter for the 41.250 Gb/s bit rate, in
accordance with the Ethernet 40GBASE-FR standard.
DSA8300 Programmer Manual
2-85
Содержание DSA8300
Страница 1: ...xx DSA8300 Digital Serial Analyzer ZZZ Programmer Manual P077057002 077 0570 02 ...
Страница 2: ......
Страница 3: ...DSA8300 Digital Serial Analyzer ZZZ Programmer Manual xx Revision B www tektronix com 077 0570 02 ...
Страница 8: ...Preface iv DSA8300 Programmer Manual ...
Страница 9: ...Getting Started ...
Страница 10: ......
Страница 15: ...Syntax and Commands ...
Страница 16: ......
Страница 404: ...Commands Listed in Alphabetical Order 2 388 DSA8300 Programmer Manual ...
Страница 405: ...Status and Events ...
Страница 406: ......
Страница 426: ...Status and Events 3 20 DSA8300 Programmer Manual ...
Страница 427: ...Examples ...
Страница 428: ......
Страница 431: ...Appendices ...
Страница 432: ......
Страница 433: ...Appendix A Character Set DSA8300 Programmer Manual A 1 ...
Страница 434: ...Appendix A Character Set A 2 DSA8300 Programmer Manual ...
Страница 446: ...Appendix C Factory Default Setup Values C 8 DSA8300 Programmer Manual ...