Displaying Waveforms
3- 122
CSA7000B Series & TDS7000B Series Instruments User Manual
Operations on Waveforms.
In general, the method of adjusting (vertically scaling,
offsetting, positioning, and so on) is from the front panel: adjust a waveform
using its Vertical Scale and Position knobs
.
Table 3--7 summarizes operations you can perform for the three waveform types.
Table 3- 7: Operations performed based on the waveform type
Control function
Waveform supports
Ch
Ref
1
Math
Operating notes
Vertical Scale
Yes
Yes
Yes
Math and reference waveforms are scaled and positioned from their
t
t l i d
Vertical Position
Yes
Yes
Yes
setup control windows.
Vertical Offset
Yes
No
No
Horizontal Scale
Yes
Yes
Yes
Waveforms are adjusted according to the Zoom Lock setting.
Horizontal Position
Yes
Yes
Yes
Horizontal Record Length
Yes
No
No
Quick Horizontal and Vertical
Scale Adjust (Zoom)
Yes
Yes
Yes
Dragging a box around a portion of the selected waveform adjusts
horizontal scale to fill the zoom graticule with the boxed portion (see
Setting MultiView Zoom Controls on
page 3--125).
1
Pixel-map reference waveforms, those saved while in fast acquisitions mode or waveform database mode, cannot be
repositioned or rescaled.
Graticules.
Select a graticule size from the Graticule Size drop-down list in the
Zoom Setup window to change the size of the acquisition waveform and zoomed
waveform windows. The 50-50 selection allocates half of the available display
for the zoomed graticule and half of the available display for the acquisition
window. The 80-20 selection allocates 80% of the available display for the
zoomed graticule and 20% for the acquisition window. Touch 100 to use the
entire display for the zoomed graticule.
Figure 3--32 on page 3--120 shows the elements of the graticules; the elements
are the same for each graticule displayed.
Operations on the Timebase.
In general, the method of adjusting (horizontally
scaling, setting resolution/record length, positioning, and so on) is from the front
panel: adjust the timebase using the Horizontal Scale, Resolution, and Position
knobs
.
Only channel waveforms can be set directly.
Table 3--7 shows how horizontal operations relate to the waveform types; the key
points follow:
H
The instrument displays a reference waveform with horizontal settings in
effect at the time it was saved. You cannot adjust these settings. See
Saving
and Recalling Waveforms
on page 3--227 for more information on reference
waveforms.
Содержание CSA7404B
Страница 4: ......
Страница 16: ...Table of Contents xii CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 24: ...Product Description 1 4 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 130: ...Acquiring Waveforms 3 62 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 186: ...Triggering 3 118 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 234: ...Measuring Waveforms 3 166 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 288: ...Creating and Using Math Waveforms 3 220 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 324: ...Data Input Output 3 256 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 330: ...MyScope 3 262 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 364: ...Appendix A Specifications A 30 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 378: ...Appendix B Automatic Measurements Supported B 14 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 414: ...Glossary Glossary 18 CSA7000B Series TDS7000B Series Instruments User Manual ...
Страница 437: ...Index CSA7000B Series TDS7000B Series Instruments User Manual Index 23 setup 3 122 C 5 C 6 Size C 5 ...
Страница 438: ...Index Index 24 CSA7000B Series TDS7000B Series Instruments User Manual ...