Calibration Procedure—442 Service
Performance Check
Figure 4-4. Timing accuracy check test setup.
18. Magnified Sweep Accuracy
a. Set:
MAGNIFIER
X10 (button in)
SEC/DIV
1
fj
SOURCE
EXT
b.
Set the time-mark generator for a .1
fjs
marker
output.
c.
CHECK—For one marker per each graticule divi
sion within 5% over the center eight graticule divisions.
Exclude the first division (50 ns) of magnified sweep and
all divisions beyond the 100th magnified division.
d. Disconnect the test setup.
19. TV Mode Check
NOTE
This step may be omitted if the 442 is not planned to
be used for displaying television sync signals. A
television receiver or any other convenient source of
television sync signals may be used as the signal
source for this check (see Table 4-1, item 7). This
step lists appropriate signal amplitudes for checking
both internal and external TV MODE Performance
Requirements.
To
check internal
triggering
(SOURCE set to CH 1/CH 2 or COMP), set the
VOLTS/DIV and VOLTS/DIV VAR to attenuate the
TV signal to one division of composite sync or 2.3
divisions of composite video on the crt display.
W A R N I N G
If a television receiver is used as the signal source,
an isolation transformer must be installed between
the receiver and its power input source if the receiver
does not have a transformer operated power supply.
a. Set:
VERT MODE
CH 1
VOLTS/DIV (CH 1)
As required
VOLTS/DIV VAR (CH 1)
As required
SEC/DIV
.1 m
TRIGGERING MODE
TV
SOURCE
CH 1/CH 2
MAGNIFIER
XI (out)
b.
Attach a compensated 10X probe to the Channel 1
input connector. Connect the probe ground lead to the
circuit ground on the television signal source and connect
the probe tip to an appropriate composite sync or
composite video test point.
c.
Set Channel 1 VOLTS/DIV and VAR to display 1
division of composite sync signal (or 2.3 divisions of
composite video signal).
d.
CHECK—That a stable triggered display of the TV
field signal can be obtained by adjusting the LEVEL and
SLOPE control settings.
e. Set the SEC/DIV switch to 50
p.
REV A MAY 1980
4-11
Содержание 442
Страница 9: ...442 Service 442 Oscilloscope viii REV A MAY 1980 ...
Страница 113: ...Figure 7 4 442 Oscilloscope block diagram REV A JUN 1980 2 3 7 4 2 7 A ...
Страница 117: ...A8 VERTICAL BOARD Figure 7 6 Vertical circuit board location ...
Страница 118: ......
Страница 120: ......
Страница 122: ......
Страница 123: ...Figure 7 8 interface circuit board location ...
Страница 124: ......
Страница 126: ......
Страница 130: ...A ll TRIGGER SWITCH BOARD 2 3 7 4 3 6 A Figure 7 10 Trigger Switch circuit board location ...
Страница 131: ...2 3 7 4 S 4 R ev jun VRSO V E R T IC A L OUT PUT CRT t PROBE ADJ 3 ...
Страница 133: ......