TABLE 6-3
Type 1A1 Bandwidth' and Risetime"
(lo a d Impedance: 50 ohms)
Performance Check— Type 1A1
System
(Instrument Types)
V VOLTS/CM Switch Positions
.005
.05
Bandwidth
Risetime
Bandwidth
Risetime
544. 546, 547, 556
Dc to
28 MHz
12.5 ns
DC to
50 MHz
7 ns
581, 581 A, 585, 585A
DC to
28 MHz
12.5 ns
DC to
50 MHz
7 ns
Using Type
81A Adapter
581, 581 A, 585, 585A
DC to
23 MHz
15 ns
DC to
33 MHz
10,5 ns
Using Type
81A Adapter
541 A, 543B, 545B
DC to
23 MHz
15 ns
DC to
33 MHz
10.5 ns
551, 555
DC to
21 MHz
16,5 ns
DC to
27 MHz
13 ns
531 A, 533A, 535A
DC to
14 MHz
25 ns
DC to
15 MHz
23 ns
536
DC to
10.5 MHz
33 ns
DC to
11 MHz
31 ns
'Upper bandwidth mea»ured at the 3 dB down point
RUetime calculated from this formula: Riietime
-
•Frequency
+ U»o upper bandwidth
limit
itoted for tho eyitom.
d, Adjust the Type 191 Variable controls so the display
is exactly 4 cm in amplitude. This is the reference ampli
tude (see Fig. 6-7A).
e, Set the Type 191 Frequency Rango switch to 42-100.
f. Without changing the Typo 191 output amplitude, in
crease tho output frequency until the vortical deflection is
reduced to 2.8 cm (see Fig. 6-7B). This is the 30% down
voltage point (equivalent to —3dB).
g. CHECK— Channel 1 upper bandwidth limit at a ver
tical deflection factor of 0.05 volts/cm should be 50 MHz
or higher.
NOTE
If the 3 dB down point is slightly less than 50
MHz consider that the accuracy of the Type 191
is within ± 2 % of the selected frequency, within
± 4 % of indicated amplitude using the 0.5-5 V
range and ± 5 * / . of indicated amplitude using the
5-50 mV range into a 50-ohm ± 1 % termination.
In addition, consider that the high-frequency re
sponse of the oscilloscope vertical amplifier must
meet its requirements.
NOTE
Risetime may be calculated using the formula
given below Table 6-3.
h. Set the Type 191 Frequency dial to 45 MHz and the
Frequency Range switch to 50 kHz Only.
i. Disconnect the signal from the Channel 1 INPUT con
nector and connect it to the Channel 2 INPUT connector.
I A) Reference amplitude at S O kH i.
L
. . . . J
—
nn
____ i , ____
n L
.
>
T
u=
\
Reduced
to
2.8 cm
i
IB! 1
J p p c ,
bandwidth limit 3-dB down point.
Fig
6 -7 . Typical CRT displays obtained when checking the upper
bandwidth limit.
Sweep rate: 0 .5 msec/cm free running.
6-9
Содержание 1A1
Страница 47: ...Maintenance Type 1A1 670 0075 01 Fig 5 5 Channel 1 Input Amplifier card 5 13 http manoman sqhill com ...
Страница 50: ...Maintenance Type 1AT Fig 5 8 Front of Output Amplifier card 5 16 http manoman sqhill com ...
Страница 128: ...ALT SWEEP SLAVE PULSE CHOPPED BLANKING ALT TRACE SYNC PULSE N 2 0 0 0 0 U P SWITCHING CIRCUIT TYPE IAI PLUG IN ...
Страница 129: ...http manoman sqhill com ...
Страница 130: ...38 ...
Страница 131: ...FIG 3 CIRCUIT CARDS ACCESSORIES CHANNEL I INPUT OUTPUT AMPLIFIER CHANNEL 2 INPUT TYPE 1A1 DUAL TRACE PLUG IN UNIT ...
Страница 134: ...Page 2 o f 2 TYPE 1A1 A p a r t i a l CHAKJKJEL Z INPUT A M P L I F I E R M16 025 1269 ...