background image

DC-390 Series User’s Manual

2

2

FCC Compliance Statement

This equipment has been tested and found to comply with limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in residential installations. This equipment generates,
uses, and can radiate radio frequency energy, and if not installed and used in accordance with
the instructions, may cause harmful interface to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause interference to radio or television equipment reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:

 

Reorient or relocate the receiving antenna

 

Move the equipment away from the receiver

 

Plug the equipment into an outlet on a circuit different from that to which the
receiver is connected

 

Consult the dealer or an experienced radio/television technician for additional
suggestions

 

Only equipment certified to comply with Class B should be attached to this equipment, and
must have shielded interface cables.

 

The FCC requires the user to be notified that any change or modifications to the equipment
by the user not expressly approved by the grantee or manufacturer could void the user's
authority to operate such equipment.

 

Each DC-390 is equipped with an FCC compliance label which shows only the FCC
Identification number: 

FCC ID: KHADC-390.

 

This device complies with Part 15 of the FCC rule. Operation is subjected to the following
two conditions: 1) This device may not cause harmful interference and 2)  This device must
accept any interference received, including interference that may cause undesired operation.

 

 

 

DC-390 Series

 

 

Tested to Comply
with FCC Standards

 

For Home or Office Use

Содержание DC-390 Series

Страница 1: ...5 DC 390U2B Wide Ultra2 SE or LVD 16 bit 80 15 DC 390U2W Wide Ultra2 SE and LVD 16 bit 80 15 U Ultra SCSI Narrow F Ultra SCSI Wide U2 Wide Ultra2 SCSI The designation DC 390 is used throughout this ma...

Страница 2: ...receiving antenna Move the equipment away from the receiver Plug the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced r...

Страница 3: ...ving which BIOS banner is displayed upon bootup If an NCR or Symbios Logic BIOS banner is displayed the problem exists If only the Tekram BIOS banner is displayed there should be no problem If the NCR...

Страница 4: ...n Utility 18 3 2 1 Show Adapter Information 19 3 2 2 Set Adapter Options 19 3 2 3 Set Devices Options 24 3 2 4 Show SCSI Devices 27 3 2 5 Low Level Format Utility 28 3 2 6 Verify Disk Utility 28 4 DOS...

Страница 5: ...2 7 2 2 For NT Versions 4 x 52 7 3 Removing the SCSI Host Adapter from the System 53 7 3 1 For NT Versions 3 x and 3 5x 53 7 3 2 For NT Versions 4 x 53 8 WINDOWS 3 X DRIVERS 54 8 1 Driver Installation...

Страница 6: ...eries User s Manual 6 6 10 3 Adding the Driver to an Existing SCO UNIX System 63 APPENDIX 64 A Specifications 64 B Product Support Form 65 C General Troubleshooting Tips 66 D Flash BIOS Programming Ut...

Страница 7: ...edia and SCSI hard drives MS DOS Windows 3 x WFWG 3 x Windows NT 3 x 4 0 Windows 95 98 OS 2 2 0 WARP 3 0 4 0 NetWare 3 x 4 x SCO Unix 3 2v4 x OpenServer 5 0 UnixWare 1 1 SVR4 2 version1 UnixWare Slack...

Страница 8: ...CSI ID number 0 6 for DC 390 390U 0 15 for DC 390F 390U2B 390U2W of each SCSI device is set properly for the host adapter Section 2 3 The maximum devices that can be installed on each model are show b...

Страница 9: ...DC 390 Series User s Manual 9 9 2 1 Board Layout The following figures illustrate the jumper and connector locations for the DC 390 Series PCI SCSI Host Adapters DC 390 Fast SCSI 2 adapter DC 390U Ult...

Страница 10: ...2 HARDWARE SETUP DC 390 Series User s Manual 10 10 DC 390F Ultra Wide SCSI 3 adapter DC 390U2B Wide Ultra2 SCSI adapter...

Страница 11: ...e used on DC 390U2B For DC 390U2W non Ultra2 devices should be kept on connectors CN1 and CN2 There are four connectors in DC 390U2W which can be separated into two independent SCSI buses using 53C141...

Страница 12: ...s occurs set JP2 to Enabled for the first adapter and Disabled for all additional DC 390s The BIOS of the first DC 390 will control all others installed 2 3 Setting the SCSI IDs Each SCSI device attac...

Страница 13: ...s adapter Leave only the terminators mounted on the last internal device and the last external device As in the above case remove the terminators from all other devices connected in between Note1 For...

Страница 14: ...ed stripe normally red aligned with Pin 1 of the connector Maximum length of the SCSI bus is determined by the number of devices and the data transfer rate The following table summarizes the maximum a...

Страница 15: ...ds having EEPROM built on board with DC 390U F U2B U2W please only use tekram driver 2 If you use DC 310 U only or with other none Symbios chip card you have to use Symbios driver not Tekram driver Th...

Страница 16: ...such as boot from SCSI device this will allow the system to boot from any bootable SCSI device connected to the DC 390 series controller Since the mainboard BIOS will automatically shadow the PCI ada...

Страница 17: ...DC 390U PCI SCSI Controller BIOS v3 04 Date 1999 2 11 Installed at IOPORT E800h IRQ 10 Level triggered BIOS ROM mapped at C800h Press F2 or F6 to enter configuration Menu Upon pressing the F2 or F6 ke...

Страница 18: ...ction During Bootup is disabled It also allows you to modify your settings without rebooting to enter the PCU When running UTIL EXE it s best to boot clean from a DOS floppy disk After powering up the...

Страница 19: ...h PCI Interrupt Line INTA IRQ 11 IRQ Trigger Type Level triggered Data Xfer Type PCI Bus Master 3 2 2 Set Adapter Options Set Adapter Options Adapter SCSI ID SCSI ID 7 Default Boot Device ID SCSI ID 0...

Страница 20: ...setting Removable media as BIOS device see page 22 should be set to Boot drive only Booting from a SCSI CD ROM The setting Boot From CD ROM see below must be Enabled for CD Changer Boot Device LUN ma...

Страница 21: ...2 and Windows NT can use either FAT or HPFS NTFS respectively For these Operating Systems the Greater Than 1GB Support feature only needs to be enabled if FAT is to be used as the file system NTFS an...

Страница 22: ...se 1 Case 2 IDE HDD 0 none Drive C Drive C IDE HDD 1 none None Drive D SCSI Device 0 Drive C Drive D SCSI Device 1 Drive D Number of drives supported by CMOS 2 has been reached Device driver must be u...

Страница 23: ...sabled default Enabled Each SCSI ID can have up to eight Logic Unit Numbers LUN 0 7 With this option enabled all the LUNs for all SCSI IDs on the SCSI bus will be scanned and recognized as BIOS Device...

Страница 24: ...enu allows you to change options for each device on the SCSI bus Device information related to each SCSI ID is displayed in the lower portion of the screen DC 390 SCSI ID 0 1 2 3 4 5 6 7 Parity Checki...

Страница 25: ...and cannot be changed Parity Checking Yes No This option defaults to enabled i e Yes If set to No the DC 390 won t perform parity checking For devices that do not implement the parity function you sh...

Страница 26: ...highest data transfer rate for compatibility with SCSI devices complying with the Fast SCSI II protocol The DC 390 will negotiate an optimum speed depending on the transfer rate of each device under t...

Страница 27: ...e Information SCSI Device Information Vender ID ST32171N Product Revision level Fixed disk SCSI Version Supported Linked Command Supported SCAM Protocol 8 Bits Disk Capacity 512 You can then move on t...

Страница 28: ...is damaged The disk drive has not been formatted with the 512B block parameter proceed Under normal circumstances it is both unnecessary and inadvisable to perform low level formatting Executing this...

Страница 29: ...se as logical drives and also recognizes data formats used by other adapter manufacturers TRMCD SYS The device driver for CD ROM and CD Changer devices This driver is loaded after ASPI SYS in the CONF...

Страница 30: ...res can be found in Chapter 3 DOS ASPI The following screens illustrate the DOS driver install procedure 1 To begin this screen displays information about the adapter number HA 0 I O port address Base...

Страница 31: ...r Y N Y Driver Y N Y Do You Want to install CD ROM 5 can have any name you choose The default path would be C DC390 for DC 390 or C DC390W for DC 390U 390F 390U2B 390U2W For this example we ll use Thi...

Страница 32: ...G SYS and AUTOEXEC BAT files This installation program will modify system CONFIG SYS by adding the following lines DEVICE C DCSCSI ASPI SYS DEVICE C DCSCSI TRMDISK SYS DEVICE C DCSCSI TRMCD EXE D CDRO...

Страница 33: ...he system and boot into DOS 2 Insert the DC 390 Driver Disk1 into your floppy drive 3 Copy the drivers and utilities into a properly named directory e g C ASPI 4 Add a line in the CONFIG SYS DEVICE C...

Страница 34: ...0 to 7 It is recommended that DOS 4 x or higher be used For DOS 3 x logical drive capacity is limited to 32M bytes The logical drive scanning sequence of TRMDISK SYS starts with adapter 0 SCSI ID 0 pr...

Страница 35: ...ge is changed 4 4 Disk Partition Utility TFDISK EXE is a disk partitioning program for modifying or creating partition tables under DOS Valid DOS partitions can be created by DOS FDISK only for drives...

Страница 36: ...ogram can be acquired from Microsoft separately 1 Add a line after the ASPI driver DEVICE C ASPI ASPI SYS DEVICE C ASPI TRMCD SYS d cdrom0 Note 1 For Trantor s Music Box you have to add one more optio...

Страница 37: ...an support the following tape backup subsystems under DOS SYTOS PLUS Tape backup program from SYTRON CORP SYTOS V3 xTape backup program from SYTRON CORP ARCserve SoloTape backup program from Cheyenne...

Страница 38: ...p information to NetWare during installation 5 1 ASPI Drivers for NetWare 5 1 1 NetWare 5 0 This subsection covers the installation of the driver module DC390R1 HAM DC390R1 DDI for DC 390 and DC 390XR...

Страница 39: ...00 4 01 4 02 4 1x 4 2 4 2SB 1 Begin the file server installation according to the instructions in the file server installation chapter in the Novell NetWare installation manual 2 After seeing a messa...

Страница 40: ...SLOT Options are 3 2 Select SLOT Option 3 When prompted for a slot number accept the slot numbers displayed This slot number is SLOT and MAINBOARD dependent 7 Write down the slot number for use below...

Страница 41: ..._312 CDSAVE 8 Change directory to the C SERVER_312 312PTD NATIVE LOADER lswap loader exe C SERVER_312 SERVER EXE CD SERVER_312 9 Enter install at DOS command line Proceed through the installation of N...

Страница 42: ...ers displayed This slot number is SLOT and MAINBOARD dependent 12 Write down the slot number for use below and press Enter to proceed In case where two DC 390U W F U2B U2W series adapters are present...

Страница 43: ...g n Using Queue Tag Option Command Line option qtagtype option Default value ORDERED Valid options ORDERED SIMPLE Function Select the type of queue tag to be used when tagged command queuing is enable...

Страница 44: ...vices including Magneto Optical MO Disks differ from Fixed Disks in that the media can be dynamically changed ejecting and inserting disks while the system is running Due to the caching capability and...

Страница 45: ...ume name of the new media is unknown it can be checked by selecting the item Volume Options after typing load install Return at the NetWare prompt Dismounting a File System To dismount a file system o...

Страница 46: ...ing procedures are for a new OS 2 installation or upgrading to a newer version of OS 2 To add a DC 390 to an existing OS 2 system see next section 1 Make a copy of the OS 2 Setup Disk 1 Label this dis...

Страница 47: ...on screen comes up click the SCSI icon at left side of SCSI Adapter Support In the Select SCSI adapter list deselect the QLogic QLA510 adapter and leave as None unless you have another SCSI adapter in...

Страница 48: ...inning of the file add the following line BASEDEV TMSCSIM ADD Note1 If OS 2 is booting from an IDE drive the line BASEDEV TMSCSIM ADD must appear after the line that loads the IDE driver e g IBM1S506...

Страница 49: ...where x starts from 0 is the order number of the adapter that was found in the system Unit switch An option that applies to device s unit I Ignore the specified adapter DM Enable DASD manager support...

Страница 50: ...ot Microsoft Windows NT from Setup Diskette NT 3 1 3 5 3 51 4 X or CD ROM NT 3 51 4 X The following is the procedure for installing the Tekram adapter driver while installing Windows NT Boot from Disk...

Страница 51: ...py the driver files Boot from CD ROM DC 390 U2B U2W You can boot from CD ROM when you set the CD ROM as a boot device from Main Board BIOS for ATAPI CD ROM or DC 390 U2B U2W boot up screen for SCSI CD...

Страница 52: ...A WINNT 3_1 3_5 For NT versions 3 1 and 3 5 A WINNT 3_51 4_x For NT versions 3 51 and 4 0 5 Windows NT will show Tekram DC 390 PCI SCSI Adapter Ver XXX Select OK 6 Windows NT will display Adapter Tekr...

Страница 53: ...then enter in the path to the driver files A WINNT 3_51 4_x 7 Restart the system 7 3 Removing the SCSI Host Adapter from the System 7 3 1 For NT Versions 3 x and 3 5x 1 From the Main Program group do...

Страница 54: ...re beginning this procedure Run DOSINST to install the Tekram ASPI Drivers 8 1 Driver Installation 1 Make sure that Windows 3 x is up and running properly 2 Insert the driver disk into your floppy dri...

Страница 55: ...am driver follow these steps 1 Open the Control Panel and double click the System Icon 2 Click the Device Manager Tab and double click SCSI Controllers 3 Select AMD PCI SCSI and click Properties 4 Cli...

Страница 56: ...double click the Add New Hardware Icon The Add New Hardware Wizard will appear 2 Choose No for Do you want Windows to search for your new hardware 3 Select SCSI Controllers for Hardware Types 4 Click...

Страница 57: ...rollers 3 Select Symbios Logic 895IU PCI SCSI Adapter for DC 390U2B U2W or AMD PCI SCSI Controller for DC 390 and click Properties 4 Click the Driver Tab and choose Update Driver The Update Device Dri...

Страница 58: ...and click Properties 6 Click the Driver Tab and choose Update Driver The Update Device Driver Wizard will appear Click Next 7 Select Search for a better driver than the one your device is using now Re...

Страница 59: ...dialog box shows driver Files directory Windows SYSTEM IOSBUSYS Trm3X5 mpd Click OK 9 A System Settings Change dialog box appears Remove the driver disk from the drive and click on Yes to restart the...

Страница 60: ...ies 4 Click the Driver Tab and choose Update Driver The Update Device Driver Wizard appears 5 Click Next 6 Choose Search for a better driver than the one your device is using now Recommended and click...

Страница 61: ...U2B U2W SCO Unix 3 2v4 x tps SCO OpenServer 5 0 ams slha 10 1 Preparing a Driver Diskette In order to install the Unix OpenServer driver a 1 44M driver diskette must be made first Download the SCO39X...

Страница 62: ...W with Openserver 5 0 skip step 4 4 When you are prompted Table io_init contains at27 another routine named amsinit please enter which routine 0 40 to replace To list a to add amsinit at the end defau...

Страница 63: ...escription NAME DESCRIPTION tps Tekram DC390 PCI SCSI Host Adapter V2 0 If you re not using DC 390 under SCO Unix3 2v4 x check the above table for corresponding command 5 Type the following command to...

Страница 64: ...he SCSI sequences in hardware Patented programmable GLITCH EATER Circuitry on REQ and ACK inputs DC 390 only Programmable Active Negation on REQ ACK and data outputs Target Command Set Support Single...

Страница 65: ..._____________________ Video card _____________________ Hard disk Floppy card 1 _____________________ 2 _____________________ Network card _____________________ Hard disk drive s 1 ____________________...

Страница 66: ...t in the PCU If the above solution does not work you must boot from a floppy and run FDISK EXE to delete the partitions Then re Fdisk and Format the drive to make it compatible with the DC 390 2 The B...

Страница 67: ...pace some software such as anti virus programs may issue false alarms 7 System Hangs very soon after the PCU setup For some specific drives such as the NEC 384 Seagate ST3283N Alps DR312D set the Max...

Страница 68: ...ween SCSI chip and CPU is that CPU will pack 100MHz if it can run 100MHz and 66MHz if can run 66MHz during production It is a natural phenomena that some chips can run higher speed and others can t do...

Страница 69: ...ensure DC 390x s proper driver installation 18 TIMEOUT Reset SCSI Bus SCSI Bus Reset Detected under NetWare Try to set Tagged Command Queuing which is in Set Devices Options of SCSI BIOS menu for the...

Страница 70: ...n n 1 4 or 5 in the PNP PCI Configuration entry a Press Del key during system s power up to enter BIOS setup menu b Select PNP PCI Configuration entry c Set Slot 2 Use IRQ NO IRQ10 2 If the mainboard...

Страница 71: ...rogramming Utility The second file needed is the updated BIN file which contains the actual BIOS code This file will have the extension bin such as INT13 BIN Make sure these files are on the diskette...

Отзывы: