BA_ECO-Cube_190815_EN.docx
34
15.08.2019
16.2.5
Electrical test of the electrical lines and earthing connections
Working on electrical voltage components and attaching the power cable
entails the risk of electric shock. Working on electrical components can
lead to serious dangers to life and limb.
The operator is responsible for ensuring that all work on electric components is
carried out by authorised and qualified personnel.
The filter unit is a "stationary electrical systems" from an electrical point of view. Those systems
are subject to regular electrical checks by the operator of the unit and are subject to national
standards of the different countries.
The here recommended maintenance interval complies with the in Germany applying "Regulation 3
of the German Social Accident Insurance - Electrical plants and equipment" (formerly known as
BGV-A3).
The check must only be carried out by a qualified electrician or a person trained in electrics using
suitable measuring and test devices. The scope of testing and the methods must be in line with the
respective national standard. All contacts in the control cabinet must be checked for tight fit, and
must be readjusted if necessary.