Visual inspection of the filter unit
Visual inspection:
Make sure that there are no visible safety-related defects.
Disconnect the filter unit from the power supply and secure it against
unauthorised switching on (see chapter 7.2).
The following steps must be carried out in the course of the visual inspection:
•
Check the unit for completeness and damages.
•
Check if all required pipeline elements, cable connections and hoses are connected to the
filter unit.
•
Check all electrical earthing connections and cables for visible damages.
•
Ensure that all parts are firmly connected.
•
Check all connection points of the filter unit for escaping dust.
•
Check all metal parts for corrosion or damages/changes of the coating.
•
Check the inner filter area and the filter housing.
•
Check the hinges of the maintenance door for damages.
•
Visual inspection of the control and operating elements as well as the outside running ca-
bles for damages.
•
Check the dust collection container for tightness, check the sealing rubber of the container.
16.2.2
Visual inspection of the pipelines for dust deposits
Visual inspection:
Observe if there are no visible safety-related defects.
Disconnect the filter unit from the power supply and secure it against
unauthorised switching on (see chapter 7.2).
The following steps must be carried out in the course of the visual inspection:
•
Open the inspection flaps of the pipeline and check the pipeline for dust deposits. Dust
deposits must be eliminated.
•
Open the service doors (pos.17) at the suction support to check the spark trap. Dust de-
posits must be eliminated.