![Teka ECO-Cube Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/teka/eco-cube/eco-cube_operating-instructions-manual_1075680018.webp)
BA_ECO-Cube_190815_EN.docx
18
15.08.2019
•
Remove the dust collector container gently from under the dust collector housing (pos.5) to
avoid disturbing the dust.
Ensure a dust free approach when transporting or disposing.
•
Remove the dust collection bag with the accumulated welding dust. Before removing the
bag must be closed using, for example, cable ties or similar.
•
Properly store or dispose of the dust collection bag with the dust in a suitable container and
according to the national or regional regulations.
•
Lay a new dust collection bag in the dust collection holder so that the opening of the bag is
placed over the edge of the dust collector container.
•
Push the dust collector container under the dust collector housing until it reaches its origi-
nal position.
•
Hang the toggle clamps on the hook of the dust collection container and close so that the
container is tightly sealed under the filter system. The seal upon the dust collection con-
tainer must be checked for any damage and replaced if necessary.
There is a threat of crushing when the toggle clamps are closed!
•
After completion of all maintenance work the system can be reconnected to the power
supply and connected to the external compressed air supply.
7.4 Draining of the condensate
Operation with compressed air results in condensation water being gradually deposited in the com-
pressed air tank. The maintenance interval depends heavily on the quality of the compressed air
and cannot, therefore, be determined in advance.
•
Open the drain valve (pos.19) with a suitable screwdriver and allow
the escaping condensate to flow into a suitable container.
When opening the drain valve a blast of compressed
air is possible! Dispose of the condensate according to the statu-
tory provisions.
•
Close the drain valve.
•
After completion of all maintenance work the system can be reconnected to the power
supply and connected to the external compressed air supply.