7.1 Cleaning the filter cartridges
Filter cleaning can be carried out in various ways. Please refer to the separately enclosed operat-
ing instructions for the system control.
Without compressed air supply the filter cartridges will become dirty very quick-
ly. The service life of the filter cartridge depends strongly on the particular conditions of
use. It cannot be determined beforehand.
7.2 Disconnection from the mains / emptying of compressed air tank
•
Switch the system off. Then disconnect the unit from the power supply.
•
Secure the system against unauthorised reconnection during the maintenance period.
•
Disconnect the external compressed air supply from the system.
•
Empty the compressed air tank by opening the drain cock (pos.19)
with a suitable screwdriver. Small amounts of condensation water
can leak out when the drain valve is opened. Close the drain valve
again when the compressed air tank is completely emptied.
When opening the drain valve a blast of com-
pressed air is possible! Dispose of the condensate according to
the statutory provisions.
•
After completion of all maintenance work the system can be reconnected to the power
supply and connected to the external compressed air supply.
7.3 Emptying the dust collector
The dust collection container must be cleaned after a certain number of operating hours. This
range depends on the amount of dust. The filling level has to be proofed at least once a week.
The filter cartridge must be cleaned before starting the emptying.
For this you have to proceed a manual cleaning via the system control (see separate manual) three
times. The filter unit must be switched off beforehand but without disconnecting the unit from the
power supply. After that the filter unit must be disconnected from the power supply and secured
against restart. Please wait for 5 minutes after the cleaning of the filter cartridge.
•
Before emptying the dust collecting container ensure a suitable container (e.g. plastic bag)
is ready.
Caution
The filter unit is delivered with a few plastic bags. Further bags are optionally available (see
spare parts list)! We recommend promptly stocking up on plastic bags.
•
Remove the toggle fasteners (pos.12), so that the rolls of the dust collector container (pos.
6) rest on the floor.