89
(30) Multi-Function Output Terminal (RA-RB-RC or R1A-R1B-R1C) Function Selection
(Sn-30)
(31) Multi-Function Output Terminal (DO1-DOG) Function Selection
(Sn-31)
(32) Multi-Function Output Terminal (DO2-DOG or R2A-R2C) Function Selection
(Sn-32)
Multi-function output terminal setting and its function as shown in Table 16.
Table 16 Multi-function output terminal function
Setting
Function
LCD Display
Description
Ref.
Page
00 During running
Running ON
:
During running
91
01 Zero speed
Zero Speed
ON
:
Zero speed
91
02 Frequency agree
Frequency Arrive Speed agree width: Cn-31
55
03 Setting frequency agree
Agreed F Arrive
ON
:
output frequency =
±
Cn-29,
Speed agree width: Cn-31
55
04
Output frequency
detection1
Freq. Det. 1
ON
:
while ACC, -Cn-29
≧
output freq.
≧
Cn-29
while DEC, -Cn-30
≧
output freq.
≧
Cn-30
Speed agree width: Cn-31
55
05
Output frequency
detection2
Freq. Det. 2
ON
:
while ACC, output freq
≧
Cn-29(or
≦
-Cn-29)
while DEC, output freq
≧
Cn-30(or
≦
-Cn-30)
Speed agree width: Cn-31
55
06 Inverter ready
Run Ready OK!
ON
:
READY
91
07 Undervoltage detected
Low Volt Detect ON
:
Undervoltage detected
91
08 Output baseblocked
Output B.B.
ON
:
Output baseblocked
91
09 Run source mode
Run Source
Operator
ON
:
Run source from digital operator (Local mode)
91
10 Frequency command mode Ref. Cmd. Operator
ON
:
Frequency command from digital operator
(Local mode)
91
11 Overtorque detected
Over Tq. Detect
ON
:
Overtorque detected
56,76
12
Frequency command
Invalid
Freq. Cmd. Invalid ON
:
Frequency command Invalid
92
13 Fault
Fault
ON
:
Fault
92
14 Pulse signal output
Pulse Mul. Output Only set by Sn-31, Sn-32 (terminal DO1-DOG)
92
15 Undervoltage alarm
Low Volt Alarm ON
:
Undervoltage alarm
92
16 Inverter overheat
Inverter Over Heat ON
:
Inverter Overheat
106
17 Motor overload
Motor Over Load ON
:
Motor Overload
79
18 Inverter Overload
Inverter Over Load ON
:
Inverter Overload
106
19 Fault retry
Fault Retry
ON
:
Retry
52
20
RS-485 communication
fault
RS-485 Fault
ON
:
RS-485 communication fault
106
21 Timer function output
Timer Function
Signal delay output (.vs. timer function input)
44,93
22
RS-485 Communication
Application
Comm. Control
Extension Output Contact application
(Please refer to ‘7200MA RS-485 MODBUS
/PROFIBUS Application Manual’)
93