66
Function
Parameter
No.
Name
LCD display
(English)
Description
Factory
Setting
Ref.
Page
Sn-40
PG Speed
Control Function
Sn-40= 0
PG Invalid
0 : without speed control
1 : with speed control
2 : with speed control but no
integration control during Acc/Dec.
3 : with speed control and integration
control during Acc/Dec.
0
96
Sn-41
Operation
Selection At PG
Open Circuit
Sn-41= 0
1st. Dec. Stop
0 : deceleration to stop (Bn-02)
1 : coast to stop
2 : deceleration to stop (Bn-04)
3 : continue to run
0
96
Sn-42
Operation Selection
At PG Large Speed
Deviation
Sn-42= 0
1st. Dec Stop
0 : deceleration to stop (Bn-02)
1 : coast to stop
2 : deceleration to stop (Bn-04)
3 : continue to run
0
96
PG Speed
Control
Sn-43
Operation Selection
At PG Overspeed
Detection Deviation
Sn-43= 0
1st. Dec. Stop
0 : deceleration to stop (Bn-02)
1 : coast to stop
2 : deceleration to stop (Bn-04)
3 : continue to run
0
96
Sn-44
Operation Mode
Selection During
Auto_Run
Sn-44= 0
Auto_Run Invalid
0 : Auto_Run mode not effective
1 :Auto_Run mode for one single
cycle. (continuing running from
the unfinished step if restarting)
2 :Auto_Run mode be performed
periodically (continuing running
from the unfinished step if restarting)
3 :Auto_Run mode for one single
cycle, then hold the speed of final
step to run. (continuing running from
the unfinished step if restarting)
4 :Auto_Run mode for one single
cycle. (starting a new cycle if
restarting)
5 :Auto_Run mode be performed
periodically (starting a new cycle
if restarting)
6 :Auto_Run mode for one single
cycle, then hold the speed of final
step to run. (starting a new cycle if
restarting)
0
97
Sn-45
Auto_Run Mode
Operation Selection1
Sn-45= 0
Auto_Run Stop
0
Sn-46
Auto_Run Mode
Operation Selection2
Sn-46= 0
Auto_Run Stop
0
Sn-47
Auto_Run Mode
Operation Selection3
Sn-47= 0
Auto_Run Stop
0
Sn-48
Auto_Run Mode
Operation Selection4
Sn-48= 0
Auto_Run Stop
0
Sn-49
Auto_Run Mode
Operation Selection5
Sn-49= 0
Auto_Run Stop
0
Auto_Run
Mode
Sn-50
Auto_Run Mode
Operation Selection6
Sn-50= 0
Auto_Run Stop
0 : stop (Bn-02)
1 : forward
2 : reverse
0
97