![TECO speecon 7200ma Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/teco/speecon-7200ma/speecon-7200ma_instruction-manual_1072473034.webp)
32
■
Example of using LCD digital operator
Note
:
Before operation: Control parameter Cn-01 value must be set as the
input AC voltage value. For example, Cn-01=380 if
AC input voltage is 380.
This example will explain the operating of 7200MA according to the following time
chart.
■
OPERATION MODE
(1)
POWER
ON
SET INPUT
VOLTAGE
FWD JOG
OPERATION
FREQUENCY
SETTING
FWD RUN
FREQ REF.
VALUE CHANGED
REV RUN
STOP
FWD
60 Hz
REV
60Hz
(2)
(3)
(4)
(5)
(6)
(7)
(8)
■
Example of operation
PRGM
DRIVE
Description
Key Sequence
Digital Operator
Display
Remark
LED
OFF
Display
for 0.5 sec
DRIVE
DSPL
press 3
times
EDIT
ENTER
RESET
EDIT
ENTER
.
Select frequency reference
value displayed
.
Select PRGM mode
.
Select
CONTROL
PARAMETER
.
Display Cn-01 setting
.
Input Voltage 380V
(1)
(2)
When Power on
Input voltage
setting (e.g. AC
input voltage is
380V )
(continued)
Freq. Cmd.000.00Hz
TECO
Entry Accepted
Cn-01 = 380.0V
Input Voltage
Cn-01 = 440.0V
Input Voltage
Cn -01-
Input Voltage
An -01
Freq. Cmd. 1
Содержание speecon 7200ma
Страница 1: ......