![TECO F510 series Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/teco/f510-series/f510-series_quick-setting-manual_1072458054.webp)
53
Error
Corrective action
08
Motor
acceleration error
(Rotational type
auto-tuning only).
Increase acceleration
time (00-14).
Disconnect motor
load.
09
Other auto-tuning
errors
Check the motor
tuning data (17-00 to
17-09).
Check motor
connection.
4.5 PM Motor Auto-tuning Error
When a fault occurs during auto-tuning of a
PM motor, the display will show the “IPErr”
fault and the motor stops. The fault
information is displayed in parameter 22-22.
Note:
The fault contact output does not
energize with an auto-tuning fault.
Refer to Table 4.4, for fault information
during tuning, cause and corrective
action.
Table 4.4 Auto-tuning fault and corrective
actions for PM motor
Error
Corrective action
01
Magnetic pole
alignment tuning
failure (static).
Check the motor
tuning data (22-02).
Check inverter
capacity
02~04 Reserved
05
Circuit tuning time
out.
Check for active
protection functions
preventing auto-
tuning.
06 Reserved
07
Other motor tuning
errors.
Check the motor
tuning data (22-02).
Check motor
connection.
08 Reserved
09
Current out of
range during circuit
tuning.
Check the motor
tuning data (22-02).
Check inverter
capacity
10 Reserved
11
Parameter tuning
and detecting time
out.
Check if the setting
value of parameter 22-
11 is too low, but its
value cannot exceed
100% of the inverter.
Check motor
connection.
Содержание F510 series
Страница 1: ......
Страница 55: ...1 1 1 1 R L1 S L2 R L1 S L2 T L3 U T1 V T2 W T3 40 IEC 61800 3 08 1 2 200V 100 400V 10 LC RC 1 3 13 00 25 11 01...
Страница 56: ...2 1 4 1 5 08 30 07 00 5 5 20Hp 15 1 6 25 10 40 60 95 RH...
Страница 57: ...3 2 2 1 NFB AC NFB NFB NFB 200mA 0 1 V TYPE AC AC EMC R S T E...
Страница 58: ...4 2 2 F510 F510 2 1 2 2 2 3...
Страница 93: ...39 4 4 PM 01 22 02 02 04 Reserved 05 06 Reserved 07 08 Reserved 09 22 02 10 Reserved 11 22 11 100...
Страница 100: ......