![TECO F510 series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/teco/f510-series/f510-series_quick-setting-manual_1072458029.webp)
28
Group 10: PID Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
Waking up
10-20
Delay Time
of PID
Waking up
0.0~255.5
0.0
10-21 Reserved
10-22
Start Level
of PID
Enable
0.00~400.00 0.00
Note2
10-23 PID Limit
0.00~100.0
100.0
*1
10-24
PID Output
Gain
0.0~25.0 1.0
10-25
PID
Reversal
Output
Selection
0: Do not Allow
Reversal
Output
0
1: Allow
Reversal
Output
10-26
PID Target
Acceleration/
Deceleration
Time
0.0~25.5
0.0
10-27
PID
Feedback
Display Bias
0~9999 0
10-28 Reserved
10-29
PID Sleep
Selection
0: Disable
1
1: Enable
2: Set by DI
10-30
Upper Limit
of PID
Target
0.0 ~ 100.0
100.0
10-31
Lower Limit
of PID
Target
0.0 ~ 100.0
0.0
10-32
PID
Switching
Function
0: PID1
0
1: PID2
2: Set by DI
3: Switch to
PID2 when
RTC Timer
Enables
10-33
PID
Maximum
Feedback
Value
1~10000 999
10-34
PID Decimal
Width
0~4 1
10-35 PID Unit
0: %
0 *6
1: FPM
2: CFM
3: PSI
4: GPH
5: GPM
6: IN
7: FT
8: /s
9: /m
10: /h
11: °F
12: inW
Group 10: PID Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
13: HP
14: m/s
15: MPM
16: CMM
17: W
18: KW
19: m
20: °C
21: RPM
22: Bar
23: Pa
24: KPa
Note4
10-36
PID2
Proportional
Gain (P)
0.00~10.00 3.00
*1
10-37
PID2
Integral
Time (I)
0.0~100.0 0.50
*1
10-38
PID2
Differential
Time (D)
0.00~10.00 0.00
*1
10-39
PID Output
Frequency
Setting during
disconnection
00.00~400.00 30.00
*6
10-40
Compensatio
n Frequency
Selection of
PID Sleep
0: Disable
0
Note1
1: Enable
10-41
~
10-43
Reserved
10-44
Precharge
Frequency
0.0~120.0
0
Note3
10-45
Precharge
Time
0~250
0
Note3
10-46
Precharge
Target Level
0~10000
0
Note3
10-47
Proportional
Gain 3(P)
0.00~10.00
3.00
Note6
10-48
Integral
Time 3(I)
0.00~100.00
0.50
Note6
10-49
Differential
Time 3(D)
0.00~10.00
0.00
Note6
Group 11: Auxiliary Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
11-00
Direction
Lock
Selection
0: Allow
Forward and
Reverse
Rotation
1
1: Only Allow
Forward
Rotation
2: Only Allow
Reverse
Rotation
Содержание F510 series
Страница 1: ......
Страница 55: ...1 1 1 1 R L1 S L2 R L1 S L2 T L3 U T1 V T2 W T3 40 IEC 61800 3 08 1 2 200V 100 400V 10 LC RC 1 3 13 00 25 11 01...
Страница 56: ...2 1 4 1 5 08 30 07 00 5 5 20Hp 15 1 6 25 10 40 60 95 RH...
Страница 57: ...3 2 2 1 NFB AC NFB NFB NFB 200mA 0 1 V TYPE AC AC EMC R S T E...
Страница 58: ...4 2 2 F510 F510 2 1 2 2 2 3...
Страница 93: ...39 4 4 PM 01 22 02 02 04 Reserved 05 06 Reserved 07 08 Reserved 09 22 02 10 Reserved 11 22 11 100...
Страница 100: ......