![TECO F510 series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/teco/f510-series/f510-series_quick-setting-manual_1072458021.webp)
20
Group 05 Multi-Speed Function Group
Code
Parameter
Name
Setting Range Default
Attribu
te
05-32
Deceleration
Time Setting
of Multi
Speed 7
0.1~6000.0
10.0
05-33
Acceleration
Time Setting
of Multi
Speed 8
0.1~6000.0
10.0
05-34
Deceleration
Time Setting
of Multi
Speed 8
0.1~6000.0
10.0
05-35
Acceleration
Time Setting
of Multi
Speed 9
0.1~6000.0
10.0
05-36
Deceleration
Time Setting
of Multi
Speed 9
0.1~6000.0
10.0
05-37
Acceleration
Time Setting
of
Multi Speed
10
0.1~6000.0
10.0
05-38
Deceleration
Time Setting
of Multi
Speed 10
0.1~6000.0
10.0
05-39
Acceleration
Time Setting
of Multi
Speed 11
0.1~6000.0
10.0
05-40
Deceleration
Time Setting
of Multi
Speed 11
0.1~6000.0
10.0
05-41
Acceleration
Time Setting
of Multi
Speed 12
0.1~6000.0
10.0
05-42
Deceleration
Time Setting
of Multi
Speed 12
0.1~6000.0
10.0
05-43
Acceleration
Time Setting
of Multi
Speed 13
0.1~6000.0
10.0
05-44
Deceleration
Time Setting
of Multi
Speed 13
0.1~6000.0
10.0
05-45
Acceleration
Time Setting
of Multi
Speed 14
0.1~6000.0
10.0
05-46
Deceleration
Time Setting
of Multi
Speed 14
0.1~6000.0
10.0
05-47
Acceleration
Time Setting
of Multi
Speed 15
0.1~6000.0
10.0
05-48
Deceleration
Time Setting
0.1~6000.0
10.0
Group 05 Multi-Speed Function Group
Code
Parameter
Name
Setting Range Default
Attribu
te
of Multi
Speed 15
Group 06 Automatic Program
Operation Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
06-00
Automatic
Operation
Mode
Selection
0: Disable
0
1: Execute a
single cycle
operation
mode. Restart
speed is based
on the previous
stopped speed.
2: Execute
continuous
cycle operation
mode. Restart
speed is based
on the previous
stopped speed.
3: After the
completion of a
single cycle,
the on-going
operation
speed is based
on the speed of
the last stage.
Restart speed
is based on the
previous
stopped speed.
4: Execute a
single cycle
operation
mode. Restart
speed will be
based on the
speed of stage
1.
5: Execute
continuous
cycle operation
mode. Restart
speed will be
based on the
speed of stage
1.
6: After the
completion of a
single cycle,
the on-going
operation
speed is based
on the speed of
Содержание F510 series
Страница 1: ......
Страница 55: ...1 1 1 1 R L1 S L2 R L1 S L2 T L3 U T1 V T2 W T3 40 IEC 61800 3 08 1 2 200V 100 400V 10 LC RC 1 3 13 00 25 11 01...
Страница 56: ...2 1 4 1 5 08 30 07 00 5 5 20Hp 15 1 6 25 10 40 60 95 RH...
Страница 57: ...3 2 2 1 NFB AC NFB NFB NFB 200mA 0 1 V TYPE AC AC EMC R S T E...
Страница 58: ...4 2 2 F510 F510 2 1 2 2 2 3...
Страница 93: ...39 4 4 PM 01 22 02 02 04 Reserved 05 06 Reserved 07 08 Reserved 09 22 02 10 Reserved 11 22 11 100...
Страница 100: ......