©2016 Tecnotion BV - All rights reserved - The contents of this document are subject to change without prior notice.
38
Tecnotion
| www.tecnotion.com | [email protected]
Ironless linear mot
or manual - v
er
. 1.03
VACUUM
AP D
APPENDIX D
Vacuum Installation
When all above safety warnings are respected the vacuum motors are in
compliance with the Machine Directive (98/37/EC) for bus voltages below
75Vdc.
COMPLIANCE WITH MACHINE DIRECTIVE FOR 75VDC TILL 250VDC
All requirements as described in “Compliance with Machine Directive for
<75Vdc” need to be implemented.
Since the cables only have single insulation for the use above 75Vdc extra
isolation needs to be added.
Extra measurements with respect to grounding, shielding (EMC) and isola-
tion need to be taken in to account depending on the application.
COMPLIANCE WITH MACHINE DIRECTIVE FOR <300VDC
All requirements as described in “Compliance with Machine Directive for
<75Vdc” and “Compliance with Machine Directive for 75Vdc till 250Vdc”
need to be implemented.
The temperature sensor cables are only rated till 250Vdc, they cannot be
used above 250Vdc.
It is not allowed to use the vacuum motors above 300Vdc.
MECHANICAL
See
3.4 Requirements for the mounting surface
for more details about the
requirements for the mounting surface
ELECTRICAL
For characteristics of PTC and NTC please see
UMV and ULV coils flying leads power and sensor cable do not
carry a (braided)shield. To comply with EMC regulation adequate
shielding needs to be provided by the customer.
Features
UMV
ULV
Bolts for coil unit (steel DIN912)
M3x10
M4x12
Tightening torque
1.0 – 2.0 Nm
2.0 – 3.0 Nm
Bolts for magnet yoke (steel DIN912)
M4x25
M5x35
Sensor Cable (color)
Connection to servo controller
Brown
PTC
White
PTC
Yellow
NTC
Green
NTC
Power Cable
Color code
Connection to servo controller
3-phases
L1
Black
3-phases
L2
Red
L3
White
Type
Coil unit flatness
Parallelism
Separation of
mounting faces
R(mm)
S(mm)
V(mm)
UMV
0.05
0.05
9.45 ±0.05
ULV
0.1
0.05
12.3 ±0.1
Table D1: Installation tolerances Vacuum U-series
Table D2: Bolts for coil unit
Table D3: Powercables wire identification
Table D4: Sensor cable wire identification
Содержание UC3 Series
Страница 1: ...Ironless linear motor manual...