©2016 Tecnotion BV - All rights reserved - The contents of this document are subject to change without prior notice.
33
Tecnotion
| www.tecnotion.com | [email protected]
Ironless linear mot
or manual - v
er
. 1.03
DIGITAL HALL MODULE
AP C
C
3-1
2-3
1-2
Induced voltage moving in cable direction
Phase 1 (+) - Phase 2 (-)
2
1
0
-1
-2
0 2 4 6 8 10 12 14 16 18 20 22 24
MOVEMENT OF ONE POLEPITCH IN CABLE DIRECTION (mm)
A
B
3 DIGITAL OUTPUTS A,B,C:
- SINK-TYPE 20mA max.
- PERIOD 24mm (UF SERIES)
- SIGNAL DEFINITION ACCORDING TO FIGURE (HIGH=SINK)
- MAXIMUM VOLTAGE DROP 0.4V + 120 * Isink (in A)
- TYPICAL VOLTAGE DROP 0.1V + 120 * Isink (in A)
- SHORT CIRCUIT SAFE @5V SUPPLY
POWERSUPPLY
- +4.5 .. + 28V DC
- 40mA
CABLE CONNECTIONS
5.8 ±0.1
O
3.2 (1m)
15
7
2.5
(2
x)
O
2.5
WHITE BROWN
GREEN YELLOW GREY
PINK
BLUE
RED
SHIELD
0 V
+4.5 .. 28V GND
HALL B
HALL A GND
GND
HALL C GND
Only one ground wire needs to be connected for proper grounding.
APPENDIX C
Digital Hall Module - UF
Содержание UC3 Series