©2016 Tecnotion BV - All rights reserved - The contents of this document are subject to change without prior notice.
36
Tecnotion
| www.tecnotion.com | [email protected]
Ironless linear mot
or manual - v
er
. 1.03
DIGITAL HALL MODULE
AP C
C
3-1
2-3
1-2
Induced voltage moving in cable direction
Phase 1 (+) - Phase 2 (-)
2
1
0
-1
-2
0 4.75 9.5 14.25 19 23.75 28.5 33.25 38 42.75 47.5 52.25 57
MOVEMENT OF ONE POLEPITCH IN CABLE DIRECTION (mm)
A
B
3 DIGITAL OUTPUTS A,B,C:
- SINK-TYPE 20mA max.
- PERIOD 57mm (UX SERIES)
- SIGNAL DEFINITION ACCORDING TO FIGURE (HIGH=SINK)
- MAXIMUM VOLTAGE DROP 0.4V + 120 * Isink (in A)
- TYPICAL VOLTAGE DROP 0.1V + 120 * Isink (in A)
- SHORT CIRCUIT SAFE @5V SUPPLY
POWERSUPPLY
- +4.5 .. + 28V DC
- 40mA
CABLE CONNECTIONS
WHITE BROWN
GREEN YELLOW GREY
PINK
BLUE
RED
SHIELD
0 V
+4.5 .. 28V GND
HALL B
HALL A GND
GND
HALL C GND
Only one ground wire needs to be connected for proper grounding.