Configuration of sensor using service adapter / Vertical menu description / Settings - Operation modes
DUT-E fuel level sensors. Operation manual. Version 8.1
©
Technoton, 2020
72
3.10.4 Settings
–
Operation modes
Operation modes
entry contains settings to configure sensor for operation in particular
conditions with compliance of tracking device requirements (see figure 49).
a) DUT-E AF b) DUT-E CAN
c) DUT-E 232/485 d) Automatic transmission e) Summator mode
mode drop-down list drop-down list
Figure 49
—
Operation mode configuration
1) Fuel level filter time
—
time interval preceding the data transmission. Fuel level value is
smoothed during this interval. Thus, fuel level value transmitted by sensor to the tracking
device is not instantaneous and is averaged over a certain period of time.
Parameter value range is 0…120 seconds with 10 second step.
Default value is 60 seconds.
Setting this parameter is very important for
mounted on vehicles operated on hilly
surfaces.