Annex E
DUT-E profile printed copy
Fuel level sensor
Passport
Model sensor
DUT-E AF
Serial number
092001302783
Firmware version
3.12
Date compil
Jan 09 2016
Time compil
09:15:05
Settings
Calibration
Actual length of sensor after trimming (mm)
685.0
Thermal compensation
Thermal compensation (-
3...3 %/°C)
0
Operation mode
Fuel level filter time, 0..120 s step=10 s
0
Address (101..108)
101
Analog output
Level min. (1.0...8.0 V):
1.000
Level max. (2.0...9.0 V):
9.000
Output signal type:
U
Output signal type:
Level
Diagnostics:
off
Calibration table
No
Level, mm
Volume, l
001
0.0
0.0
002
63.9
10.0
003
130.4
20.0
004
215.0
30.0
005
300.0
40.0
006
408.6
50.0
007
510.5
60.0
008
603.7
70.0
009
685.0
80.0
Parameters of sensor calibration
Frequency of calibration "free", Hz
2309.99
Frequency of calibration "free", Hz
1200.94