Annex C SPN of CAN UP 27 Functional modules
CAN UP 27 online telematics gateway. Operation manual. Version 1.0
© Technoton, 2017
64
SPN
Name
Factory
value
Unit of
measure
Range
Clarification
Calibration Table Input 2
(
PGN 63153
)
521365
Physical input
type
Frequency
kHz
0.001…10
Select ―frequency‖ type of physical signal input from the
drop-down list.
A user can disable ―frequency‖ type of input. In this
case, all the input settings will not be available for
editing.
521366
Signal input
value
0; 10000 Hz
On the fact 0…4294970000 Frequency input values are saved as points of the
calibration table for input 2. By default, the table contains
two points corresponding to extreme values of the range
in which input signal is changing. Maximum of 10
calibration points can be saved.
In the software, after pressing "Graph" button, you will
see a graph displaying in accordance with calibration table
a relation between converted SPN parameter values and
input signal level.
521347
SPN value
0; 4800 Rpm
On the fact 0…4294970000 Converted SPN parameter values are saved as points of
the calibration table for input 2. By default, the table
contains two points corresponding to extreme values of
the range in which parameter is changing. Maximum of 10
calibration points can be saved.
In software window, you will see current value and chart
of converted SPN parameter change in real time.
Inputs Settings
(
PGN 63100
)
521364
Input Number
No
No
No
Select I3 group of contacts of discrete physical input of
CAN UP27.
521150
PGN
64960
Passenger
counter
No
0…65535
Enter output PGN, which will contain SPN parameter
converted from discrete signal.
PGN can be selected through Service software from the
list, containing most important Vehicle parameters, or
from the extended S6 DB list.
1214
SPN
3044
Silent alarm
status
No
0…524287
Select PGN, which should be resulted from converting
discrete signal.
521188
S6 Address
(SA)
100
No
0…255
Enter unique network address (SA) of CAN UP 27
connected via S6.
SA cannot be edited if PGN is sent ―on request‖.
521362
PGN Sending
Period
0
ms
0…4294970000 Enter time interval (in ms) of sending generated PGN
via S6. For ―on request‖ sending, enter 0 ms.
Calibration Table Input 3
(
PGN 63154
)
521365
Physical input
type
Discrete
No
U
PS
…3
(«0»)
3…0 («1»)
(U
PS
— voltage
of power supply
source)
Select ―discrete‖ type of physical signal input from the
drop-down list.
A user can disable ―discrete‖ type of input. In this case,
all the input settings will not be available for editing.
521366
Signal input
value
0; 3 V
On the fact
0…4294970000 Discrete input values, which correspond to two states of
pressing panic button, are saved as points of the
calibration table for input 3.
In the software, after pressing "Graph" button, you will
see a graph displaying in accordance with calibration table
a relation between converted SPN parameter values and
input signal level.
521347
SPN value
«1»;«0»
On the fact
0…4294970000 As calibration table points for input 3, enter two states
of pressed panic button, corresponding to ―0‖ and ―1’
values.
In software window, you will see current value and chart
of converted SPN parameter change in real time.