SPN
Name
Factory
value
Unit of
measure
Range
Clarification
521393
/10.2 Axle weight Mode
border /
10.2 Load
15000
kg
0…32127.5
Enter axle load value, which will be a boundary between
―not loaded‖ and ―loaded‖ operation modes
(see figure C.5).
521393
/10.3 Axle weight Mode
border /
10.3 Overload
25000
kg
0…32127.5
Enter axle load value, which will be a boundary between
―loaded‖ and ―overloaded‖ operation modes. If boundary
is exceeded, Telematics system will recognize ―Overload‖
Event (see figure C.5).
11)
Events registrator FM – designed for registration of 15 important and 15 informative
latest Events.
Table C.11 — Events registrator FM. Displayed and/or editable SPN with the help of
Software Service CAN UP
SPN
Name
Factory value Unit of measure
Clarification
List of important Events
PGN 63055
521166
SPN Events
No
No
Displayed list of an important Events (up to 15).
Important events are:
- electrical network is defective;
- panic button pressed.
Each Event is indicated with: name, date/time, and
also additional information (if its available).
Evets are displayed chronologically, starting for the
latest one. When maximum possible number of
displayed Events reached the new Events are recorded
on the place of previous, starting from the oldest
erased Events.
List of informative Events
PGN 63056
521166
SPN Events
No
No
Displayed list of informative Events (up to 15).
Informative Events are:
- power supply is turned on/off;
- GNSS signals appearance and disappearance.
Each Event is indicated with: name, date/time, and
additional information (if its available).
Evets are displayed chronologically, starting from the
latest one. When maximum possible number of
displayed Events reached the new Events are recorded
on the place of previous, starting from the oldest
erased Events.
User can erase list of informative events.
Detailed parameters description (
SPN
), structure and content of messages (
PGN
) of FM
CAN UP 27
are placed at the following web site
http://s6.jv-technoton.com/en
(to access
S6 DB
registration is required).