3- Contact After Sales Service
Error 8 : Short circuit stylus
The pin assembly cable is cut or
damaged
Check the pin assembly cable
condition and restart the
controller
The connector of the pin
assembly is not plugged
properly, or damaged
Check the connector of the pin
assembly cable and restart the
controller
The marking head cable is cut
or damaged
Check the marking head cable
condition, and restart the
controller
If still at fault, call After Sales
Service
Error 9: Open circuit
The pin assembly cable is cut or
damaged
Check the pin assembly cable
condition and restart the
controller
The connector of the pin
assembly is not plugged
properly, or damaged
Check the connector of the pin
assembly cable and restart the
controller
The marking head cable is cut
or damaged
Check the marking head cable
condition and restart the
controller
Contact After Sales Service
Error 10 : weak current
The pin assembly cable is cut or
damaged
Check the pin assembly cable
condition and restart the
controller
The connector of the pin
assembly is not plugged
properly, or damaged
Check the pin assembly cable
connector and restart the
controller
If still at fault, call After Sales
Service
Error 13 : Missing marking head The marking cable is not
correctly connected to the
controller
Check that the marking head is
correctly connected and the
connector locked then restart