Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 7.41
7.15.1.
P
OWERED MODELS
Figure 7.15-1
6.
Remove the secondary shaft assembly from
the belt and place it on a work bench.
7.
Remove the spacer
(d)
and the pin
(e)
from
the flywheel assembly.
Figure 7.15-2
To disassemble the copper disk:
8.
Back off the
6 screws
(f)
using a 4mm
hexagonal wrench.
CAUTION: Take particular care with
the copper disk, as it bends easily and
may then cause problems after
reassembly, by brushing against the
winding block.
CAUTION: During reassembly, lock
down the screws (f) using a torque
wrench setting of 6Nm.
To reassemble the secondary shaft assembly,
carry out the above steps in reverse order.
CAUTION: After completing the
reassembly, carry out the adjustment
procedure described in paragraphs: 8.1.
“Belt tension” and 8.4. “Align the belt
connecting the primary and secondary