Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 6.38
Are there sources of
electromagnetic noise near the
receiver?
Receiver Board defective.
Replace it.
NO
4
The problem does not
depend on the equipment
YES
A
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Check the correct display SW version, according to the “EXCITE SW SMART TABLE” you
can find in
TG Direct
section.
HR/HS RECEIVER (Chest Belt/Hand Sensor): Only for 700 and 700VISIO models.
Check the grounding of the
HR/HS Receiver
, measuring the resistance value between:
•
The ground fast on of
HR/HS Board
and the ground node on the Power supply box of the
machine;
•
The ground node on the Power supply box of the machine and the main wall socket.
The measured value should be approximately lower than 1Ω (Ohm).
Check finally the grounding of the main wall socket, measuring that the following voltages are
present:
P – N
(phase – neutral)
= 220Vac / 110 Vac
P – G
(phase – ground)
= 220Vac / 110 Vac
N – G
(neutral – ground)
= 0 Vac
Continued on following page....
Содержание WAVE EXCITE+
Страница 1: ...W WA AV VE E E X C I T E REV 4 1...
Страница 2: ......
Страница 4: ......
Страница 10: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina vi Page intentionally left blank...
Страница 32: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 2 20 Page intentionally left blank...
Страница 50: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 3 18 Page intentionally left blank...
Страница 184: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 9 26 Page intentionally left blank...
Страница 186: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 10 2 Page intentionally left blank...
Страница 197: ......